Endovenous mechanochemical ablation of great saphenous vein incompetence using the ClariVein device: a safety study.
نویسندگان
چکیده
PURPOSE To evaluate the feasibility and safety of endovenous mechanochemical ablation (MOCA) for the treatment of great saphenous vein (GSV) incompetence. METHODS The newly developed ClariVein device uses a technique that combines mechanical endothelial damage using a rotating wire with the infusion of a liquid sclerosant. Heating of the vein and tumescent anesthesia are not required; only local anesthesia is utilized at the insertion site. In a pilot study, 30 limbs in 25 patients (18 women; mean age 52 years) with GSV incompetence were treated with MOCA using polidocanol at 2 centers. Initial technical success, complications, patient satisfaction, and classification by venous clinical severity score (VCSS) were assessed 6 weeks after the treatment. RESULTS Initial technical success of MOCA was 100%. There were no major adverse events. Minor complications consisted of 9 local ecchymoses at the puncture site and superficial phlebitis that resolved within a week in 4 limbs. Duplex ultrasonography at 6 weeks showed 26 (87%) of 30 veins were completely occluded; 3 veins showed partial recanalization in the proximal (n = 2) and distal GSV. One patient had full segment recanalization and was successfully retreated. The VCSS significantly improved at 6 weeks (p < 0.001). Patient satisfaction was high, with a median satisfaction of 8.8 on a 0-10 scale. CONCLUSION This study showed that endovenous MOCA, using polidocanol, is feasible and safe in the treatment of GSV incompetence. Larger studies with a prolonged follow-up are indicated to prove the efficacy of this technique in terms of obliteration rates.
منابع مشابه
Retrograde mechanochemical ablation of the small saphenous vein for the treatment of a venous ulcer.
We present the first case of retrograde ablation of the small saphenous vein to treat active venous ulceration. A 73-year-old gentleman with complicated varicose veins of the left leg and a non-healing venous ulcer despite previous successful endovenous treatment to his left great saphenous vein underwent mechanochemical ablation of his small saphenous vein with the ClariVein® system, under loc...
متن کاملClariVein® – Early results from a large single-centre series of mechanochemical endovenous ablation for varicose veins
Objectives This study assessed the effectiveness and patient experience of the ClariVein® endovenous occlusion catheter for varicose veins from a large single-centre series in the UK. Methods A total of 300 patients (371 legs) underwent ClariVein® treatment for their varicose veins; 184 for great saphenous vein (GSV) incompetence, 62 bilateral GSV, 23 short saphenous vein (SSV), 6 bilateral SSV...
متن کاملMechanochemical tumescentless endovenous ablation: final results of the initial clinical trial
OBJECTIVE The purpose of this study was to assess the safety and efficacy of the ClariVein(®) system that employs mechanochemical ablation of the great saphenous vein (GSV). METHOD Patients eligible for ablation of the GSV underwent micropuncture access with only local anaesthesia to insert a 4 or 5 Fr sheath. The ClariVein(®) catheter was placed through the sheath, the wire was extruded, and...
متن کاملMechanochemical endovenous Ablation versus RADiOfrequeNcy Ablation in the treatment of primary great saphenous vein incompetence (MARADONA): study protocol for a randomized controlled trial
BACKGROUND Radiofrequency ablation (RFA) is associated with an excellent outcome in the treatment of great saphenous vein (GSV) incompetence. The use of thermal energy as a treatment source requires the instillation of tumescence anesthesia. Mechanochemical endovenous ablation (MOCA) combines mechanical endothelial damage, using a rotating wire, with the infusion of a liquid sclerosant. Tumesce...
متن کاملMechanochemical endovenous ablation of small saphenous vein insufficiency using the ClariVein(®) device: one-year results of a prospective series.
OBJECTIVE This study evaluated the feasibility, safety and 1-year results of mechanochemical endovenous ablation (MOCA™) of small saphenous vein (SSV) insufficiency. DESIGN Prospective cohort study. MATERIALS AND METHODS Fifty consecutive patients were treated for primary SSV insufficiency with MOCA™ using the ClariVein(®) device and polidocanol. Initial technical success, complications, pa...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists
دوره 18 3 شماره
صفحات -
تاریخ انتشار 2011