On iterative reconstruction in the nonlinearized polarization tomography
نویسنده
چکیده
We give uniqueness theorem and reconstruction algorithm for the nonlinearized problem of finding the dielectric anisotropy f of the medium from non-overdetermined polarization tomography data. We assume that the medium has uniform background parameters and that the anisotropic (dielectric permeability) perturbation is described by symmetric and sufficiently small matrix-function f . On a pure mathematical level this article contributes to the theory of non-abelian Radon transforms and to iterative methods of inverse scattering.
منابع مشابه
Comparing IDREAM as an Iterative Reconstruction Algorithm against In Filtered Back Projection in Computed Tomography
Introduction: Recent studies of Computed Tomography (CT) conducted on patient dose reduction have recommended using an iterative reconstruction algorithm and mA (mili-Ampere) dose modulation. The current study aimed to evaluate Iterative Dose Reduction Algorithm (IDREAM) as an iterative reconstruction algorithm. Material and Methods: Two CT p...
متن کاملFast System Matrix Calculation in CT Iterative Reconstruction
Introduction: Iterative reconstruction techniques provide better image quality and have the potential for reconstructions with lower imaging dose than classical methods in computed tomography (CT). However, the computational speed is major concern for these iterative techniques. The system matrix calculation during the forward- and back projection is one of the most time- cons...
متن کاملDISCRETE TOMOGRAPHY AND FUZZY INTEGER PROGRAMMING
We study the problem of reconstructing binary images from four projections data in a fuzzy environment. Given the uncertainly projections,w e want to find a binary image that respects as best as possible these projections. We provide an iterative algorithm based on fuzzy integer programming and linear membership functions.
متن کاملEvaluation of iterative reconstruction method and attenuation correction on brain dopamine transporter SPECT using anthropomorphic striatal phantom
Objective(s): The aim of this study was to determine the optimal reconstruction parameters for iterative reconstruction in different devices and collimators for dopamine transporter (DaT) single-photon emission computed tomography (SPECT). The results were compared between filtered back projection (FBP) and different attenuation correction (AC) methods.Methods: An anthropomorphic striatal phant...
متن کاملArtifact reduction techniques in Cone Beam Computed Tomography (CBCT) imaging modality
Introduction: Cone beam computed tomography (CBCT) was introduced and became more common based on its low cost, fast image procedure rate and low radiation dose compared to CT. This imaging modality improved diagnostic and treatment-planning procedures by providing three-dimensional information with greatly reduced level of radiation dose compared to 2D dental imaging modalitie...
متن کامل