Stethoscopes: a potential vector of infection?
نویسندگان
چکیده
STUDY OBJECTIVES To survey emergency care providers about their stethoscope-cleaning measures and to determine the correlation between these measures and the extent of Staphylococcus carriage. DESIGN Prospective cross-sectional analysis. SETTING University-affiliated community hospital ED. PARTICIPANTS One hundred fifty health care providers, comprising emergency medicine house staff and attending physicians (n = 50), ED nurses (n = 50), and prehospital personnel working in Kent County, Michigan (n = 50). INTERVENTIONS Providers were asked how often they cleaned their stethoscopes and which cleaning agents were used. We then cultured each stethoscope by pressing the diaphragm on mannitol agar and incubating the culture aerobically for 48 hours. Staphylococcus aureus was identified by means of standard measures. We examined the effects of different cleaning agents on 24 stethoscopes. The numbers of colony-forming units (CFUs) before and after cleaning with alcohol, nonionic detergent, and antiseptic soap were noted. RESULTS Overall, 48% of health care providers (74 of 150) cleaned their stethoscopes daily or weekly, 37% monthly, and 7% yearly; and 7% had never cleaned their stethoscopes. No significant differences were found in the hygiene routines of the three groups of providers surveyed. Use of an alcohol swab was the preferred method of cleaning. One hundred thirty-three stethoscopes (89%) grew staphylococci; 25 (19%) yielded S aureus. Mean staphylococcal bacterial counts ( +/- SD) were 52 +/- 78 CFUs per stethoscope among physicians, 46 +/- 92 CFUs among emergency medical service personnel, and 13 +/- 21 CFUs from the nursing staff (ANOVA, P = .01). Cleaning the stethoscope diaphragm resulted in immediate reduction in the bacterial count: by 94% with alcohol swabs, 90% with nonionic detergent, and 75% with antiseptic soap. CONCLUSION Our results confirm that stethoscopes used in emergency practice are often contaminated with staphylococci and are therefore a potential vector of infection. This contamination is greatly reduced by frequent cleaning with alcohol or nonionic detergent.
منابع مشابه
Study of Bacterial Contamination of Mobile Phones and Stethoscopes in Neonatal Intensive Care Unit
Mobile phones and stethoscopes used in neonatology units could be colonized by potentiel bacteria pathogens. It can be a vector of severe nosocomial infections and multi-drug-resistant pathogens. The aim of this study is to evaluate the microbial contamination of mobile phones and stethoscopes, used by medical and paramedical staff. The study was conducted in neonatal intensive care unit (NICU)...
متن کاملThe stethoscope - a vector of infection?
The Stethoscope— A Vector of Infection? To the Editor: In the course of investigating a hospital-wide outbreak of methicillin resistant Staphylococcus aureus, 67 physicians' stethoscopes were cultured. Both the bell and the diaphragm were sampled with a sterile cotton swab, and this was immediately streaked onto Columbia Nutrient Agar (BBL), a selective medium for grampositive organisms. The ca...
متن کاملShould we Recommend Stethoscope Disinfection Before Daily Usage as an Infection Control Rule?
Background: Many studies have shown that contaminated medical equipments act like a vector for crossinfection. Infection control programmes are effective in decreasing hospital-acquired infection rate, however, the implementation of such programmes is hindered by poor compliance of health care workers. Methods: Random selection of health care workers, at our institution, was given questionnaire...
متن کاملBacterial Contamination and Disinfection of Stethoscopes: A Knowledge Gap among Health Care Personnel of a Tertiary Care Hospital of Rural Bengal
Universal use of stethoscope for examination of patients by health care personnel makes it a potential source for spread of nosocomial infection. A cross sectional study was conducted in a tertiary care centre of Eastern Bengal during August-September 2013 to find out incidence and spectrum of bacterial contamination of stethoscopes and knowledge, attitude and practice about cleaning of stethos...