Standard reference materials: standard quartz cuvettes for high-accuracy spectrophotometry.

نویسندگان

  • R Mavrodineanu
  • J W Lazar
چکیده

Accurate knowledge of lightpath and parallelism of cuvettes used in spectrophotometry are indispensable parameters that must be determined when accurate transmittance measurements of liquid materials are considered. A description is given of the design and techniques developed at NBS for production of quartz cuvettes (SRM 932) having a nominal radiation pathlength of 10 mm ± 0.03 mm. For each cuvette, pathlength and parallelism are certified with an uncertainty of ±0.0005 mm. The method and instrumentation used to determine these parameters are also described. Additional Keyphrases: lightpath #{149} instrumental path-

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

On-line hyphenation of hydride generation with in situ trapping flame atomic absorption spectrometry for arsenic and selenium determination.

The analytical performances of coupled hydride generation, integrated atom trap (HG-IAT) atomizer flame atomic absorption spectrometry (FAAS) systems were evaluated for determination of As and Se in biological and environmental reference materials. Arsenic and Se hydrides are atomized in air-acetylene flame-heated IAT. A new design of HG-IAT-FAAS hyphenated technique that would exceed the opera...

متن کامل

Standard Reference Materials Standard Reference Material 2538 for Polarization-Mode Dispersion (Non-Mode-Coupled)

Certain commercial equipment, instruments, or materials are identified in this paper in order to specify the experimental procedure adequately. Such identification is not intended to imply recommendation or endorsement by the National Institute of Standards and Technology, nor is it intended to imply that the materials or equipment identified are necessarily the best available for the purpose. ...

متن کامل

Implementing infrared determination of quartz particulates on novel filters for a prototype dust monitor.

Research by the National Institute for Occupational Safety and Health (NIOSH) has pursued quartz analysis for the specialized filter assemblies of a new worker-wearable personal dust monitor (PDM). The PDM is a real-time instrument utilizing a tapered element oscillating microbalance (TEOM). Standard fiberglass TEOM filters cannot accommodate the desired P-7 infrared analytical method used by t...

متن کامل

Stepwise complexometric determination of aluminium, titanium and iron concentrations in silica sand and allied materials

BACKGROUND This study aimed at measuring the quantities of Al, Ti and Fe in silica sand and allied materials employing a complexometric method in the same analyte and a stepwise indirect titration with EDTA. The method involves the complexation of Al, Ti and Fe with excess EDTA and the selective de-complexation of TiO-EDTA and Al-EDTA complexes with tartaric acid and NaF respectively. In additi...

متن کامل

HemoCue haemoglobin systems--a clarification.

The preferred method to verify the accuracy of a haemoglobinometer is the International Committee for Standardization in Haematology (ICSH) reference measurement of haemoglobin as haemiglobincyanide in whole blood, using a spectrophotometer which has been calibrated directly by the WHO/ICSH primary international reference standard or by means of a commercial standard that has been manufactured ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Clinical chemistry

دوره 19 9  شماره 

صفحات  -

تاریخ انتشار 1973