Background: Delayed or missed diagnosis of critical and cyanotic congenital heart disease (CHD) in asymptomatic newborns may result in significant morbidity and mortality. The aim of this study was to determine the accuracy of pulse oximetry screening performed on the first day of life for the early detection of critical and cyanotic CHD in apparently normal newborns. Methods: This cross-sectional study used postductal pulse oximetry to evaluate term neonates born between 2008 and 2011 with normal physical examinations. Functional oxygen saturation < 95% was considered abnormal, and second measurement was done 2 hours later. If the second measurement remained < 95%, an echocardiogram was performed. On enrolment in the study, the following data for each neonate were recorded: gestational age, gender, birth weight, mode of delivery, and mother's age. Results: During the study period, totally 3,846 newborns were evaluated. Of the whole study population, 304 (7.9%) babies had a postductal functional saturation < 95%. The second measurement was also < 95% in 104 (2.7%) neonates. The mean age of the neonates at the time of pulse oximetry was 18.91 ± 8.61 (min = 4.5 and max = 49) hours. Forty-nine percent of the subjects were female and 51% were male. Echocardiography was performed on 81 out of 104 newborns, and 14 (0.36%) of them had CHD. The types of CHD in our patients were tetralogy of Fallot (3 cases), transposition of the great vessels (2 cases), double-outlet right ventricle (2 cases), truncus arteriosus, total anomalous pulmonary venous return, atrioventricular septal defect, pulmonary atresia, persistent pulmonary hypertension, ventricular septal defect, and atrial septal defect (1 case for each type). The best time for pulse oximetry was within 8-24 hours of the newborns' life. Conclusion: Pulse oximetry screening along with clinical examination may be able to assist in the early detection of critical and cyanotic CHD in asymptomatic newborns.
منابع مشابه
Evaluation of Pulse Oximetry in the Early Detection of Congenital Heart Diseases in Newborns
Background: Congenital heart diseases, which are asymptomatic at birth, are the most important causes of infant mortality. This study aimed to evaluate the role of pulse oximetry in the early detection of congenital heart diseases among newborns.Methods: In this cross-sectional descriptive study, 1230 newborns who were born in university hospitals in an urban area of Iran were placed unde...
متن کاملبررسی نتایج پالس اکسیمتری دست و پا در تشخیص زودهنگام بیماریهای قلبی مادرزادی سیانوتیک در نوزادان متولد شده در بیمارستان شبیه خوانی کاشان در 6 ماهه اول سال 1385
Background : Delayed diagnosis of critical and cyanotic congenital heart diseases in asymptomatic newborns can lead to significant morbidity and mortality in this age group. The aim of this study was to determine the utility of hand and foot oxygen saturation as a screening test for the early detection of critical and cyanotic congenital heart diseases in asymptomatic newborns in the first da...
متن کاملEvaluation of Pulse Oximetry in the Early Diagnosis of Cardiac and NonCardiac Diseases in Healthy Newborns
Background: Critical congenital heart diseases (CCHDs) are among the most common birth malformations. This study aimed to determine the cardiac and noncardiac diseases in the Iranian healthy newborns using pulse oximetry (POX) as a suggested screening method.Methods: In this cross-sectional study, healthy term and near term neonates who were born from October 2017 to March 2018 were evalu...
متن کاملScreening of Congenital Heart Disease in Newborns by Physical Examination and Pulse Oximetry in a Tertiary Care Center in Western Maharashtra
Objectives: To detect Congenital Heart Diseases (CHD) at an early stage and to find out its occurrence in asymptomatic healthy term newborns. To assess the role of pulse oximetry as a screening tool in CHD. Methods: All apparently healthy newborns delivered in a period of 1 year in Krishna Institute of Medical Sciences, Karad were screened for the presence of CHD by physical examination and pul...