Haemolysis in patients with ventricular assist devices: major differences between systems.

نویسندگان

  • Claudia Heilmann
  • Ulrich Geisen
  • Christoph Benk
  • Michael Berchtold-Herz
  • Georg Trummer
  • Christian Schlensak
  • Barbara Zieger
  • Friedhelm Beyersdorf
چکیده

INTRODUCTION Implantation of a ventricular assist device (VAD) is a seminal therapeutic option for patients with terminal cardiac failure. However, haemolysis remains a clinically relevant adverse effect of several VAD types. Lysed erythrocytes release lactate dehydrogenase (LDH) and haemoglobin. Free haemoglobin in plasma is bound by haptoglobin with high affinity. The complex is internalised by monocytes/macrophages and degraded. Any more released free haemoglobin is captured by haemopexin. This complex also undergoes lysosomal degradation in various cells. Only now, the excessive free haemoglobin can be measured in plasma. Here, we investigated haemolysis in patients supported by different VAD types. METHODS Five patients with an intracorporeal centrifugal left ventricular VAD (LVAD), 10 patients with an axial LVAD and seven patients with a paracorporeal biventricular assist device (BVAD) were analysed preoperatively and 3 days (3.0+/-0.4 days, early), 2 weeks (14+/-1 days, intermediate) and 2 months (62+/-5 days, later) after VAD implantation for haptoglobin, haemopexin, free haemoglobin in plasma, LDH, total haemoglobin, haematocrit and transfusion requirements. RESULTS Patients with a centrifugal LVAD displayed normal haptoglobin and haemopexin, low free haemoglobin and moderately increased LDH. In comparison, axial LVADs were accompanied by lower haptoglobin and haemopexin and higher free haemoglobin and LDH values. In contrast, BVADs led to an almost complete loss of haptoglobin and haemopexin and to high levels of free haemoglobin and LDH at each analysed time point. CONCLUSIONS While severe haemolysis accompanies BVAD support, erythrocyte damage is less pronounced in the axial LVAD examined and only slight in the intracorporeal centrifugal LVAD. Haemopexin, a scavenger of free haemoglobin, can be used, in combination with haptoglobin and free haemoglobin, to assess erythrocyte damage.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Design an Equivalent Left Ventricular Assist Device for Medical Equipment Labs

LVAD is a mechanical pump supporting a weak heart function and blood flow. Sometimes, the heart may not recover fast enough to take over the pumping action immediately after surgery, in such patients a temporary support device has been employed to maintain the pumping action until the patient’s own heart recovers. This device can be considered as a temporary alternative before the process of ar...

متن کامل

Pump-induced haemolysis: a comparison of short-term ventricular assist devices.

Centrifugal pumps are superior to roller pumps for extended support durations in terms of pump-induced haemolysis. In this study, we evaluated the commonly used Biomedicus BP 50 and compared it with the Jostra Rotaflow and a standard roller pump in an in vitro test circuit. Each circuit was run for a six-day period and repeated five times. Plasma haemoglobin values showed the roller pump to bec...

متن کامل

Focused Review on Transthoracic Echocardiographic Assessment of Patients with Continuous Axial Left Ventricular Assist Devices

Left ventricular assist devices (LVADs) are systems for mechanical support for patients with end-stage heart failure. Preoperative, postoperative and comprehensive followup with transthoracic echocardiography has a major role in LVAD patient management. In this paper, we will present briefly the hemodynamics of axial-flow LVAD, the rationale, and available data for a complete and organized echo...

متن کامل

The Evaluation of Survival in Patients Who Need Intra Aortic Balloon Pump (IABP) after Cardiac Surgery

Introduction: Insome cases, assist devices are required to ensure an adequate cardiac output after cardiac surgery. Intra-aortic balloon pump (IABP) is the most commonly used cardiac assist device, which provides first-line support for patients with heart failure. The aim of this study was to determine factors affecting the mortality rate of patients receiving IABP. Materials & Methods:  In thi...

متن کامل

Role of percutaneous left ventricular assist devices in preventing cerebral ischemia

Percutaneous left ventricular assist devices improve hemodynamics in acute heart failure. The devices can be deployed rapidly and with a low risk of complications, and may thereby offer potential advantages compared with surgical assist systems in the critically ill. Cerebral hypoperfusion with cerebral injury is a major challenge in acutely ill cardiac patients, especially when cardio–pulmonar...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery

دوره 36 3  شماره 

صفحات  -

تاریخ انتشار 2009