A novel object-independent "balanced" reference scan for echo-planar imaging.
نویسندگان
چکیده
Interleaved echo-planar imaging (EPI) is susceptible to significant ghosting artifacts, resulting primarily from system time delays that cause data matrix misregistration. Most EPI applications rely on "reference scans" to measure delays, and post-processing algorithms are used to correct these errors. Unfortunately, delay estimates made with most reference scan techniques are object dependent, since they are biased by magnetic field inhomogeneities and chemical shift. The current work describes the effects of field inhomogeneities and their influence on system time delay estimation. Subsequently, a new, object-independent "balanced" reference method using two readout echo trains is proposed for time delay measurements.
منابع مشابه
Effect of Phase-Encoding Reduction on Geometric Distortion and BOLD Signal Changes in fMRI
Introduction Echo-planar imaging (EPI) is a group of fast data acquisition methods commonly used in fMRI studies. It acquires multiple image lines in k-space after a single excitation, which leads to a very short scan time. A well-known problem with EPI is that it is more sensitive to distortions due to the used encoding scheme. Source of distortion is inhomogeneity in the static B0 field that ...
متن کاملA referenceless Nyquist ghost correction workflow for echo planar imaging of hyperpolarized [1‐13C]pyruvate and [1‐13C]lactate
Single-shot echo planar imaging (EPI), which allows an image to be acquired using a single excitation pulse, is used widely for imaging the metabolism of hyperpolarized 13 C-labelled metabolites in vivo as the technique is rapid and minimizes the depletion of the hyperpolarized signal. However, EPI suffers from Nyquist ghosting, which normally is corrected for by acquiring a reference scan. In ...
متن کاملMulti-echo segmented k-space imaging: an optimized hybrid sequence for ultrafast cardiac imaging.
Cardiac magnetic resonance imaging requires high temporal resolution to resolve motion and contrast uptake with low total scan times to avoid breathing artifacts. While spoiled gradient echo (SPGR) imaging is robust and reproducible, it is relatively inefficient and requires long breath-holds to acquire high time resolution movies of the heart. Echo planar imaging (EPI) is highly efficient with...
متن کاملSuper-resolved spatially encoded single-scan 2D MRI.
Single-scan MRI underlies a wide variety of clinical and research activities, including functional and diffusion studies. Most common among these "ultrafast" MRI approaches is echo-planar imaging. Notwithstanding its proven success, echo-planar imaging still faces a number of limitations, particularly as a result of susceptibility heterogeneities and of chemical shift effects that can become ac...
متن کاملNavigator-Free Dynamic Phase Correction for Echo-Planar Imaging Based Functional MRI
INTRODUCTION In dynamic echo-planar imaging (EPI), such as functional MRI, where a time series of EPI images are collected, there is additional modulation along echo readout due to changes in hardware states (e.g., temperature) that the standard reference scan based phase correction methods [1-3] cannot account for, thereby resulting in an increase of ghost level over time. To address this prob...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of magnetic resonance imaging : JMRI
دوره 9 6 شماره
صفحات -
تاریخ انتشار 1999