Quantitation of serum free light chains does not compensate for serum immunofixation only when screening for monoclonal gammopathies.

نویسندگان

  • Klas Böer
  • Thomas Deufel
چکیده

BACKGROUND Detection of plasma cell dyscrasias (PCD) requires screening of serum and urine for monoclonal proteins. Several studies have demonstrated increased sensitivity and specificity when measurement of serum free light chain (SFLC) is part of the screening protocol. In addition, omission of immunofixation (IFE) in the standard work-up that includes SFLC assay has been proposed. This study attempts to define the role of the SFLC assay in a screening strategy limited to serum only. It compares outcomes to a serum-only screening strategy that omits serum IFE. METHODS Serum from 691 patients was analysed for the presence of monoclonal protein using standard serum IFE, serum protein electrophoresis (SPE) and measurement of SFLC. Data were analysed retrospectively. RESULTS Specificity and sensitivity of abnormal SFLC-ratios for the detection of monoclonal protein using IFE were 96% and 41%, respectively. Eighteen patients with negative monospecific and Bence Jones IFE, but abnormal SFLC-ratios were identified. In most cases, this could be attributed to kidney and inflammatory disease or haematological disorders. In four cases, this resulted in further diagnostic investigation and light chain disease was later detected in two cases. Light chain disease was confirmed in one case but not confirmed in the other patient. In 14 patients, Bence Jones IFE was negative, although the concentrations of SFLC suggested the presence of monoclonal Bence Jones protein at concentrations detectable by IFE. Thus, either the anti-serum failed at detection, there was polymerisation of the free light chains or the SFLC assay overestimated protein concentrations. Simulating a work-up that included IFE only if abnormalities were detected by SPE or the SFLC assay would have resulted in 26% fewer IFEs being performed, but three patients with monoclonal proteins by IFE would have been missed. CONCLUSIONS Abnormal SFLC concentrations are neither sensitive nor specific for the detection of monoclonal proteins by IFE. Not all PCD are accompanied by excessive production of SFLC, and several other conditions, such as renal disease are associated with increased SFLC concentrations. An abnormal SFLC-ratio is a specific marker for PCD, and occurs primarily in patients with haematological disease. If renal and inflammatory diseases are excluded, this should prompt further diagnostic investigation. Screening of serum without performing an IFE as a standard procedure leads to a reduction of sensitivity when compared to screening of serum that includes IFE.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Serum Free Light Chains: An Alternative Test to Urine Bence Jones Proteins When Screening for Monoclonal Gammopathies

Background: Retrospective analyses have established the role of quantitative serum free light chains (FLCs) in the diagnosis of monoclonal light chain disorders. The aims of this study were to assess (a) whether the addition of serum FLCs to serum protein electrophoresis (SPEP) identified additional patients with monoclonal gammopathies; (b) whether serum FLC measurements could replace urinalys...

متن کامل

Serum free light chains: an alternative to the urine Bence Jones proteins screening test for monoclonal gammopathies.

BACKGROUND Retrospective analyses have established the role of quantitative serum free light chains (FLCs) in the diagnosis of monoclonal light chain disorders. The aims of this study were to assess (a) whether the addition of serum FLCs to serum protein electrophoresis (SPEP) identified additional patients with monoclonal gammopathies; (b) whether serum FLC measurements could replace urinalysi...

متن کامل

Alpha, beta, gamma of serum proteins: a long history of successfully resolved problems

Characterization of blood proteins for clinical purposes was initiated in the middle of the nineteenth century and serum protein electrophoresis was first developed in the 1930s by a Swedish biochemist Arne Tiselius. Today, clinical analysis of human serum proteins by the electrophoretic method that evolved from the original fluid method of Tiselius, through paper electrophoresis, cellulose ace...

متن کامل

Comparison of capillary zone and immunosubtraction with agarose gel and immunofixation electrophoresis for detecting and identifying monoclonal gammopathies.

Capillary zone electrophoresis (CZE) and immuno-subtraction electrophoresis (ISE) were evaluated for ability to detect and immunotype monoclonal proteins, compared with agarose gel electrophoresis (AGE) and immunofixation electrophoresis (IFE), respectively. Six hundred seventeen serum samples were analyzed with CZE and AGE to determine sensitivity and specificity in detecting IFE-confirmed mon...

متن کامل

Serum Free Light-chain Assay for the Diagnosis, Management, and Prognosis of Multiple Myeloma

In recent decades, new serum biomarkers have been developed for routine laboratory practice, such as assaying serum free light chains and more recently, assaying immunoglobulin heavy and light chain isotypes (Hevylite). In this work, we highlight the interest of new biomarkers (Hevylite Test) in the management of monoclonal gammopathies because of the technical advantages it confers and the se...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry and laboratory medicine

دوره 47 9  شماره 

صفحات  -

تاریخ انتشار 2009