Frequency and significance of a small distal ICA in carotid artery stenosis.

نویسندگان

  • J E Dix
  • B J McNulty
  • D F Kallmes
چکیده

PURPOSE Accurate calculation of the percentage of stenosis is crucial for identifying candidates for endarterectomy. Our goal was to quantify the reduction in diameter of the distal internal carotid artery (ICA) as a function of proximal ICA stenosis and to discuss the implications of distal ICA narrowing on the calculation of percentage of stenosis using the criteria of the North American Symptomatic Carotid Endarterectomy Trial (NASCET). METHODS We retrospectively reviewed the carotid angiograms of 81 patients referred for evaluation of carotid stenosis. The caliber of the ICA stenosis and the diameters of the normal distal ICA, the common carotid artery, and the internal maxillary artery were remeasured with precision calipers. The percentage of stenosis derived from the NASCET criteria were compared with vessel diameter and with the difference in size of the ipsilateral and contralateral distal ICAs. We then recalculated the percentage of stenosis by substituting the presumed normal contralateral distal ICA diameter for the ipsilateral distal ICA diameter. RESULTS In carotid arteries without significant stenosis (<70%), the distal ICA diameter measured 5.94+/-1.10 mm, but in vessels with severe stenosis (>70%), the distal ICA diameter measured 4.69+/-1.23 mm. After recalculation, four of 26 vessels were upgraded in classification from moderate (40% to 69%) to severe (>70%) stenosis. CONCLUSION The diameter of the distal ICA begins to decrease when the proximal stenosis is 60% or greater. If the ICA distal to a stenosis is smaller than the contralateral ICA, recalculating the percentage of stenosis by substituting measurements of the contralateral distal ICA diameter may be warranted.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Carotid angioplasty and stenting in a patient with high grade stenosis of Internal Carotid Artery associated with both vertebral arteries and contralateral carotid occlusion

Severe internal carotid artery (ICA) stenosis is a common cause of cerebrovascular accident (CVA) in middle-aged patients. Contralateral carotid occlusion (CCO) in patients with severe ICA stenosis is associated with high risk of CVA. Carotid endarterectomy (CEA) is associated with more complications in patients with CCO than those without CCO. In this study, we present the case of a 61-year-ol...

متن کامل

بررسی یافته های سونوگرافی داپلر عروق کاروتید اکستراکرانیال بیماران مبتلا به سکته مغزی (Anterior circulation) بر اساس محدوده گرفتاری در سی تی اسکن

Background and purpose : Ârterial embolism is one of the most prevalent cause of transient ischemic attack (TÏÂ) and other types of brain ischemias and about 5o% of TÏÂ patiens have vascular stenosis. Therefore the presence of mild atherosclerotic plaques in carotid arteries, as a source of embdlism in causing TÏÂ and other brain strokes are of a great importance. Ïn present study the ...

متن کامل

تاثیر انسداد شریان کاروتید داخلی (ICA) در میزان مرگ ومیر وعوارض بیماران تحت عمل جراحی گرافت شریان کرونری(CABG)

Background and Aim: Stroke is an important cause of morbidity and mortality in patients undergoing coronary artery bypass (CABG) surgery. There are various mechanisms that can cause prioperative strokes in patients undergoing CABG other than Carotid Artery disease. The goal of this study is to evaluate whether the presence of stenosis internal carotid artery (ICA) influences prioperative stroke...

متن کامل

Diagnosing carotid stenosis near-occlusion by using CT angiography.

BACKGROUND/PURPOSE Identification of carotid near-occlusion is essential before calculation of percent stenosis because stroke risk is lower than other severe stenosis and the treatment benefit is less. Calculations with reduced distal diameters are fallacious. CT angiography (CTA) is convenient and accurately quantifies internal carotid artery (ICA) stenosis. METHODS In a blinded protocol, 2...

متن کامل

Imaging of distal internal carotid artery by ultrasonography with a 3.5-MHz convex probe.

BACKGROUND AND PURPOSE Conventionally, carotid ultrasonography has been performed with a 7.5-MHz linear probe to evaluate the extracranial internal carotid artery (ICA). However, usually only the carotid bulb or proximal portion of the ICA can be evaluated. We attempted to evaluate the distal extracranial ICA with a 3.5-MHz convex probe. METHODS The subjects were 17 consecutive patients with ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • AJNR. American journal of neuroradiology

دوره 19 7  شماره 

صفحات  -

تاریخ انتشار 1998