Comparison of a rapid readout biological indicator for steam sterilization with four conventional biological indicators and five chemical indicators.

نویسندگان

  • W A Rutala
  • S M Jones
  • D J Weber
چکیده

OBJECTIVE In this study, we compare a new biological indicator that provides results within 3 hours with four conventional, 48-hour biological indicators and five chemical indicators. DESIGN Biological indicators tested included the conventional Attest 1262, Proof Plus, Assert, and Biosign, and the new Attest 1292 Rapid Readout biological indicator. Chemical indicators tested included Comply, Propper, Chemdi, Sterigage, and Thermalog S. Spore survival following 121 degrees C in a gravity displacement sterilizer was measured by media color change after incubation for 24 and 48 hours at 56 degrees C for the conventional biological indicators, fluorescence at 3 hours for the Attest 1292 Rapid Readout biological indicator, and color change for the chemical indicators. Each exposure time was replicated 12 times with 5 samples of each indicator per run (ie, 60 replicates per indicator). RESULTS At 48 hours, the conventional biological indicators Attest 1262, Proof Plus, Assert, and Biosign showed 100%, 95%, 88%, and 93% spore survival at 5 minutes' exposure 0%, 0%, 0% and 8% at 10 minutes; and all showed 0% survival at 15 minutes' exposure. Following a 3-hour incubation, the Attest 1292 Rapid Readout biological indicator showed fluorescence at 100%, 72%, and 0% at 5, 10, and 15 minutes, respectively. The chemical indicators Comply, Propper, Chemdi, Sterigage, and Thermalog S revealed sterilization failure rates of 100%, 100%, 100%, 100%, and 100% at 5 minutes' exposure; 0%, 0%, 0%, 92%, and 100% at 10 minutes; and 0%, 0%, 0%, 3%, and 27% at 15 minutes' exposure, respectively. CONCLUSIONS The sensitivity of the Attest 1292 Rapid Readout biological indicator parallels that of conventional biological indicators. These data suggest that a 3-hour rapid readout biological indicator is equivalent to a standard 48-hour biological indicator. Some chemical indicators (eg, Thermalog S) failed to indicate adequate sterilization at 15 minutes' exposure. These chemical indicators have the potential of causing unnecessary recall of adequately sterilized items.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Monitoring steam sterilization of surgical instruments: a dilemma.

The study of two biological indicators in monitoring "flash" sterilization demonstrated that indicator construction often leads to a false interpretation of spore survival.

متن کامل

Developing the Use of Quality Indicators in Sterilization Practices

BACKGROUND Health-care-associated infections are a major threat to the safety of patient care. Control of such problem is a major criterion for hospital accreditation. This study was aimed to determine the developing use of chemical (class 6 products) and biological indicators in Tabriz district hospitals since 1997 to 2011. METHODS We conducted this time-trend interventional study with all o...

متن کامل

Effectiveness of Bench Top Non-Vacuum Autoclaves on Dental Turbine Chamber Sterilization

Introduction: Dental turbine chamber is a suitable reservoir for living microorganisms, so chamber sterilization is necessary for reducing cross contamination risk. On the other hand, in non-vacuum autoclaves, steam penetration into turbine chamber is doubtful, while they are still in use in dental clinics. In this study, performance of small non-vacuum autoclave in turbine chamber sterilizatio...

متن کامل

A preliminary evaluation of a reusable digital sterilization indicator prototype.

BACKGROUND Sterilization of critical and semicritical instruments used in patient care must undergo a terminal process of sterilization. Use of chemical and physical indicators are important in providing information on the sterilizer's performance during each cycle. Regular and periodic monitoring of sterilizers using biological indicators is necessary in periodically validating performance of ...

متن کامل

Peracetic acid: a practical agent for sterilizing heat-labile polymeric tissue-engineering scaffolds.

Advanced biomaterials and sophisticated processing technologies aim at fabricating tissue-engineering scaffolds that can predictably interact within a biological environment at the cellular level. Sterilization of such scaffolds is at the core of patient safety and is an important regulatory issue that needs to be addressed before clinical translation. In addition, it is crucial that meticulous...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Infection control and hospital epidemiology

دوره 17 12  شماره 

صفحات  -

تاریخ انتشار 1996