Tympanometry with 226 and 1000 Hertz tone probes in infants.

نویسندگان

  • Luciana Macedo de Resende
  • Juliana Dos Santos Ferreira
  • Sirley Alves da Silva Carvalho
  • Isamara Simas Oliveira
  • Iara Barreto Bassi
چکیده

UNLABELLED This study aimed at describing and analyzing tympanometric results obtained with 226 Hz and 1000 Hz probe tones; checking for correlations between tympanometry, otoacoustic emissions and otoscopic examination; describing abnormal results found in the evaluation procedures. METHODS Double-blind and prospective study. Our sample included 70 babies, between 7 days and one month and 13 days of age, without risk indicators for hearing loss, evaluated in the State Neonatal Hearing Screening Program. Transient evoked otoacoustic emissions, otoscopic examination and tympanometry with 226 Hz and 1000 Hz probe tones were used as assessment tools. The study was approved by the Ethics Committee from the institution. RESULTS Statistically significant differences were observed (p<0.05) in the tympanometric measures correlation and also between transient evoked otoacoustic emissions and compliance obtained with both probe tones. Most test results were within the normal range (94.28%). Three children (4.28%) were referred to diagnostic follow-up and one (1.42%) had middle ear dysfunction confirmed by otoscopy and 1000 Hz tympanometry. CONCLUSIONS 1000 Hz tympanometry is the most reliable probe tone used to evaluate children under three months of age. More studies focusing on middle ear acoustics and mechanics are necessary to provide reliable and precise interpretation in the evaluation of middle ear functions in babies.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Accoustic immitance measures in infants with 226 and 1000 hz probes : correlation with otoacoustic emissions and otoscopy examination Summary

Audi ological evaluation in infants should include the middle ear (immitance measures and otoscopy) and also a cochlear evaluation. Aim: To check which tympanometry tone test (226 Hz or 1000 Hz), transient otoacoustic emissions and otoscopy. Methods: Transient otoacoustic emissions were taken from sixty infants ranging from zero to four months of age. The babies were assigned to two groups of 3...

متن کامل

Accoustic immitance measures in infants with 226 and 1000 hz probes: correlation with otoacoustic emissions and otoscopy examination.

UNLABELLED Audiological evaluation in infants should include the middle ear (immitance measures and otoscopy) and also a cochlear evaluation. AIM To check which tympanometry tone test (226 Hz or 1000 Hz), transient otoacoustic emissions and otoscopy. METHODS Transient otoacoustic emissions were taken from sixty infants ranging from zero to four months of age. The babies were assigned to two...

متن کامل

Normative multifrequency tympanometry in infants and toddlers.

Multifrequency tympanometry data were measured multiple times between the ages of four weeks and two years from 33 infants/toddlers. Tympanograms were also measured from 33 adult participants. Tympanograms recorded with five probe-tone frequencies (226, 400, 630, 800, and 1000 Hz) were classified using the Vanhuyse et al model classification system (Vanhuyse et al, 1975). Admittance at +200 daP...

متن کامل

The role of high frequency tympanometry in newborn hearing screening programme.

BACKGROUNDS AND OBJECTIVE The hearing assessment of the newborns ideally should detect both middle and inner ear functions. The aim of this study is to control the association between otoscopic evaluation, multifrequency tympanometry and TEOAE results. METHODS Fifty new-borns otherwise healthy were tested after the otolaryngological evaluation by 226 and 1000 Hz tympanometries and transient e...

متن کامل

Multifrequency tympanometry in neonatal intensive care unit and well babies.

BACKGROUND Conventional low probe tone frequency tympanometry has not been successful in identifying middle ear effusion in newborn infants due to differences in the physiological properties of the middle ear in newborn infants and adults. With a rapid increase in newborn hearing screening programs, there is a need for a reliable test of middle ear function for the infant population. In recent ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Brazilian journal of otorhinolaryngology

دوره 78 1  شماره 

صفحات  -