Reevaluation and application of the dual-isotope plasma ratio method for the measurement of intestinal cholesterol absorption in the hamster.

نویسندگان

  • S D Turley
  • M W Herndon
  • J M Dietschy
چکیده

These experiments systematically evaluated the dual-isotope plasma ratio method for measuring intestinal cholesterol absorption in the hamster. It was found that while the ratio of the 3H- and 14C-labeled cholesterol in the plasma, relative to the respective dose of each that was given, became constant by 72 h after their administration, the percent cholesterol absorption was lower in animals that were fasted before dosing (35.7 +/- 5.5%) than in their fed controls (47.5 +/- 3.7%). Furthermore, the percent absorption found 72 h after dosing varied greatly, depending on whether the intragastric dose of labeled cholesterol was administered in medium chain triglyceride (MCT) oil (46.2 +/- 2.3%), olive oil (63.9 +/- 11.2%), or safflower oil (74.6 +/- 4.5%). The level of absorption was not different between hamsters that had unrestricted (46.3 +/- 1.6%) and restricted (43.8 +/- 2.2%) access to their stools during the 72 h after dosing. Other experiments, using only hamsters in the fed state and MCT oil as the intragastric dosing medium, showed that the percent cholesterol absorption could be made to vary over a wide range using treatments known to produce such effects in humans. Thus, feeding either surfomer, cholestyramine, ursodeoxycholic acid, or CI-976, a new inhibitor of acyl-CoA:cholesterol acyltransferase, significantly blocked cholesterol absorption, whereas the addition of either cholic acid or increasing amounts of oil to the diet had the opposite effect. The modified dual-isotope plasma ratio method described here provides a simpler and more physiologic approach to the routine measurement of cholesterol absorption in the hamster and similar small animal models.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Percent cholesterol absorption in normal women and men quantified with dual stable isotopic tracers and negative ion mass spectrometry.

Percent cholesterol absorption was measured in 94 normal subjects aged 17- 80 years while consuming diets generally low in cholesterol (mean intake = 226 +/- 126 mg/day). A new dual stable isotope method was used where a cholesterol tracer containing 6 extra mass units was given intravenously and another tracer with 5 extra mass units was given orally during a standard test meal. The ratio of t...

متن کامل

Investigation of Intestinal Absorption of Pyridinones in Rat

Recently, it has been shown that a number of hydroxypyridinones such as 1,2-dimethyl-3-hydroxypyridin-4-one (L1) are useful for the treatment of iron overload in place of desferrioxamine in thalassaemic patients. In this study, the intestinal absorption (I.A.) of L1 and one of its analogues namely 2-methy-3-hydroxypyridin-4-one (L2), which possesses a higher partition coefficient (Kpart) than L...

متن کامل

Investigation of Intestinal Absorption of Pyridinones in Rat

Recently, it has been shown that a number of hydroxypyridinones such as 1,2-dimethyl-3-hydroxypyridin-4-one (L1) are useful for the treatment of iron overload in place of desferrioxamine in thalassaemic patients. In this study, the intestinal absorption (I.A.) of L1 and one of its analogues namely 2-methy-3-hydroxypyridin-4-one (L2), which possesses a higher partition coefficient (Kpart) than L...

متن کامل

Mechanism of hypocholesterolemic action of S-8921 in rats: S-8921 inhibits ileal bile acid absorption.

The mechanism of the hypocholesterolemic action of S-8921, methyl 1-(3,4-dimethoxyphenyl)-3-(3-ethylvaleryl)- 4-hydroxy-6,7,8-trimethoxy-2-naphthoate, was examined in rats. In diet-induced hypercholesterolemic rats, 2 weeks oral administration of S-8921 dose- and time-dependently decreased plasma cholesterol level in the daily dose range of 0.1 to 10 mg/kg. Results with the dual-isotope plasma ...

متن کامل

Determination of 137Ba Isotope Abundances in Water Samples by Inductively Coupled Plasma-optical Emission Spectrometry Combined with Least-squares Support Vector Machine Regression

A simple and rapid method for the determination of 137Ba isotope abundances in water samples by inductively coupled plasma-optical emission spectrometry (ICP-OES) coupled with least-squares support vector machine regression (LS-SVM) is reported. By evaluation of emission lines of barium, it was found that the emission line at 493.408 nm provides the best results for the determination...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of lipid research

دوره 35 2  شماره 

صفحات  -

تاریخ انتشار 1994