Deep Infections After Syndesmotic Fixation With a Suture Button Device.

نویسندگان

  • Amanda J Fantry
  • Seth W O'Donnell
  • Chris T Born
  • Roman A Hayda
چکیده

Suture button devices such as the TightRope (Arthrex, Naples, Florida) have been increasingly used for syndesmotic fixation of ankle fractures. Despite proposed advantages, prior studies have shown equivalent outcomes, with a theoretical decreased need for removal of hardware. Complications of suture button fixation of syndesmotic instability may be underreported and include lateral suture knot inflammation with or without granuloma formation, infection, aseptic osteolysis with widening of the tibial drill tunnels, heterotopic ossification, and osteomyelitis. In this case series, the authors review the current literature and describe 3 patients with TightRope fixation for syndesmotic instability who developed deep infection. The authors believe that braided suture within suture button devices may provide an environment conducive to the propagation of infection across the syndesmotic fixation tract. Evidence of suture button migration or osteolysis of the TightRope tract should prompt an infectious workup and removal of hardware. If there is concern for infection associated with the TightRope, the authors recommend removing both metallic buttons and the entirety of the suture to prevent harboring a nidus for further infection. [Orthopedics. 2017; 40(3):e541-e545.].

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Novel Suture Button Construct for Acute Ankle Syndesmotic Injuries; A Prospective Clinical and Radiological Analysis.

  Background: The importance of the syndesmosis in ankle stability is well recognized. Numerous means of fixation have been described for syndesmotic injuries including the suture button technique. Significant cost limits the use the commercially available options. We, therefore, designed a cheap and readily available alternative construct. We aim to assess the results of using a novel suture-...

متن کامل

A systematic review of suture-button versus syndesmotic screw in the treatment of distal tibiofibular syndesmosis injury

BACKGROUND Now, using a suture-button device to treat distal tibiofibular syndesmotic injuries is overwhelming due to its advantages over screw fixation. Current systematic review was conducted to make a comparison between suture-button fixation and traditionally screw fixation in the treatment of syndesmotic injuries. The outcomes included functional outcomes, implant removal, implant failure,...

متن کامل

Flexible stabilization of the distal tibiofibular syndesmosis: clinical and biomechanical considerations: a review of the literature

Syndesmotic rupture is present in 10 % of ankle fractures and must be recognized and treated to prevent late complications. The method of fixation is classically rigid fixation with one or two screws. Knowledge of the biomechanics of the syndesmosis has led to the development of new dynamic implants to restore physiologic motion during walking. One of these implants is the suture-button system....

متن کامل

Suture Button Fixation for Syndesmosis Injuries: Review of the Literature

Syndesmosis injuries -also known as high ankle sprainshave an increasing popularity because of an increased awareness of diagnosis. Different from lateral ankle sprains, mechanism of injury mostly involves external rotation, eversion and excessive dorsiflexion. Other mechanisms can also cause sydesmosis injuries. Because of high levels of missed injuries the real prevalence of syndesmosis injur...

متن کامل

Comparison of a novel Fiberwire-button construct versus metallic screw fixation in a syndesmotic injury model.

BACKGROUND There is minimal experience with less rigid syndesmotic fixation devices which may approximate the normal distal tibio-fibular mechanics during healing. This study evaluates the ability of a FiberWire-button implant (Arthrex, Naples, FL) to maintain syndesmotic reduction as compared with a metallic screw. METHODS Ten matched fresh-frozen cadaveric ankle pairs with intact ligaments ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Orthopedics

دوره 40 3  شماره 

صفحات  -

تاریخ انتشار 2017