Fast automatic linear off-resonance correction method for spiral imaging.
نویسندگان
چکیده
Field inhomogeneity and susceptibility variations, coupled with a long readout, can result in image blurring in spiral imaging. Many correction methods based on a priori off-resonance information, such as an acquired field map, have been proposed in the literature. Automatic off-resonance correction methods are alternative approaches that estimate a field map from the image data themselves. In this paper we propose a fast automatic off-resonance correction method that performs linear correction without acquiring a field map. The method requires only about two times the total computation time compared to image reconstruction by gridding. It can also be used in combination with a full field map automatic off-resonance correction method to increase the extent of correction. The method is demonstrated by in vivo coronary artery imaging.
منابع مشابه
Block regional off-resonance correction (BRORC): a fast and effective deblurring method for spiral imaging.
One primary disadvantage of spiral imaging is blurring artifact due to off-resonance effects. The conventional frequency segmented off-resonance correction method that is performed over the entire image is computationally intense due to the large number of fast Fourier transforms (FFTs) required. Here, a new fast off-resonance correction method, block regional off-resonance correction (BRORC), ...
متن کاملFast conjugate phase image reconstruction based on a Chebyshev approximation to correct for B0 field inhomogeneity and concomitant gradients.
Off-resonance effects can cause image blurring in spiral scanning and various forms of image degradation in other MRI methods. Off-resonance effects can be caused by both B0 inhomogeneity and concomitant gradient fields. Previously developed off-resonance correction methods focus on the correction of a single source of off-resonance. This work introduces a computationally efficient method of co...
متن کاملNovel Motion Correction Technique Using Orbital Navigator Echoes in Interleaved Spiral Imaging
Spiral imaging does not produce apparent flow artifacts. However, it remains sensitive to rapid rigid body motion. In this abstract, a motion correction technique using an orbital navigator “ring” in interleaved spiral imaging is presented. In this technique, a circular k-space trajectory is incorporated into each spiral interleaf. Data inconsistency due to both rotation and translation can be ...
متن کاملNovel automatic off-resonance correction without field maps in spiral imaging using L1 minimization
Corrected image using the field map (a) (d) The field map created using phase-based correction (c) Novel automatic off-resonance correction without field maps in spiral imaging using L1 minimization Hisamoto Moriguchi, Kohki Yoshikawa, Morio Shimada, Shin-ichi Urayama, Yutaka Imai, Manabu Honda, and Takashi Hanakawa Radiology, Tokai University, Isehara, Kanagawa, Japan, Radiological Sciences, K...
متن کاملCorrection of physiologically induced global off-resonance effects in dynamic echo-planar and spiral functional imaging.
In functional magnetic resonance imaging, a rapid method such as echo-planar (EPI) or spiral is used to collect a dynamic series of images. These techniques are sensitive to changes in resonance frequency which can arise from respiration and are more significant at high magnetic fields. To decrease the noise from respiration-induced phase and frequency fluctuations, a simple correction of the "...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Magnetic resonance in medicine
دوره 56 2 شماره
صفحات -
تاریخ انتشار 2006