Stent thrombogenicity early in high-risk interventional settings is driven by stent design and deployment and protected by polymer-drug coatings.

نویسندگان

  • Kumaran Kolandaivelu
  • Rajesh Swaminathan
  • William J Gibson
  • Vijaya B Kolachalama
  • Kim-Lien Nguyen-Ehrenreich
  • Virginia L Giddings
  • Leslie Coleman
  • Gee K Wong
  • Elazer R Edelman
چکیده

BACKGROUND Stent thrombosis is a lethal complication of endovascular intervention. Concern has been raised about the inherent risk associated with specific stent designs and drug-eluting coatings, yet clinical and animal support is equivocal. METHODS AND RESULTS We examined whether drug-eluting coatings are inherently thrombogenic and if the response to these materials was determined to a greater degree by stent design and deployment with custom-built stents. Drug/polymer coatings uniformly reduce rather than increase thrombogenicity relative to matched bare metal counterparts (0.65-fold; P=0.011). Thick-strutted (162 μm) stents were 1.5-fold more thrombogenic than otherwise identical thin-strutted (81 μm) devices in ex vivo flow loops (P<0.001), commensurate with 1.6-fold greater thrombus coverage 3 days after implantation in porcine coronary arteries (P=0.004). When bare metal stents were deployed in malapposed or overlapping configurations, thrombogenicity increased compared with apposed, length-matched controls (1.58-fold, P=0.001; and 2.32-fold, P<0.001). The thrombogenicity of polymer-coated stents with thin struts was lowest in all configurations and remained insensitive to incomplete deployment. Computational modeling-based predictions of stent-induced flow derangements correlated with spatial distribution of formed clots. CONCLUSIONS Contrary to popular perception, drug/polymer coatings do not inherently increase acute stent clotting; they reduce thrombosis. However, strut dimensions and positioning relative to the vessel wall are critical factors in modulating stent thrombogenicity. Optimal stent geometries and surfaces, as demonstrated with thin stent struts, help reduce the potential for thrombosis despite complex stent configurations and variability in deployment.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Acute Thrombogenicity of a Durable Polymer Everolimus-Eluting Stent Relative to Contemporary Drug-Eluting Stents With Biodegradable Polymer Coatings Assessed Ex Vivo in a Swine Shunt Model.

OBJECTIVES This study sought to evaluate whether the permanent fluoropolymer-coated Xience Xpedition everolimus-eluting stent (Xience-EES) exhibits lower acute thrombogenicity compared with contemporary drug-eluting stents (DES) with biodegradable polymer coatings in an acute swine shunt model. BACKGROUND Previous pre-clinical and clinical experience suggests that several factors may influenc...

متن کامل

Comparison of biolimus eluted from an erodible stent coating with bare metal stents in acute ST-elevation myocardial infarction (COMFORTABLE AMI trial): rationale and design.

AIMS Compared with bare metal stents (BMS), early generation drug-eluting stents (DES) reduce the risk of revascularisation in patients with ST-elevation myocardial infarction (STEMI) at the expense of an increased risk of very late stent thrombosis (ST). Durable polymer coatings for controlled drug release have been identified as a potential trigger for these late adverse events and this has l...

متن کامل

Optimal Stent Expansion by Stent Balloon Multiple Inflation at Nominal Pressure in Resistant Lesions: A New Technique

Introduction: This study aimed to evaluate the effects of four-time inflation of the stent balloon at nominal pressure on optimal stent expansion in resistant lesions. Materials and Methods: This interventional study was conducted on 39 patients with coronary artery lesions, in whom Zotarolimus-eluting stents (N=20), Paclitaxel-eluting stents (N=11) and other stents (N=8) were deployed four tim...

متن کامل

Dual Antiplatelet Therapy After Drug-Eluting Stents Should Be Continued for More Than One Year and Preferably Indefinitely

Since its introduction, percutaneous coronary intervention (PCI) has been limited by 2 major factors: restenosis and vessel closure attributable to thrombosis. The use of coronary stents has had a marked beneficial impact on rates of restenosis.1,2 However, the vessel trauma that occurs during PCI induces platelet activation, and all currently available coronary stents are made of metal and are...

متن کامل

In vivo evaluation of biocompatible intravascular stents coated by inkjet printing

Inkjet–printing technology was used to apply biodegradable and biocompatible polymeric coatings of poly(D, L lactide) with the antiproliferative drugs simvastatin (SMV) and paclitaxel (PCX) on coronary metal stents. A piezoelectric dispenser applied coating patterns of very fine droplets (300 xL) and ink jetting was optimized to develop uniform, accurate and reproducible coatings of high yields...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 124 19  شماره 

صفحات  -

تاریخ انتشار 2011