The association between Femoral Tilt and impingement-free range-of-motion in total hip arthroplasty
نویسندگان
چکیده
BACKGROUND There is a complex interaction among acetabular component position and antetorsion of the femoral stem in determining the maximum, impingement-free prosthetic range-of-motion (ROM) in total hip arthroplasty (THA). By insertion into the femoral canal, stems of any geometry follow the natural anterior bow of the proximal femur, creating a sagittal Femoral Tilt (FT). We sought to study the incidence of FT as measured on postoperative computed tomography scans and its influence on impingement-free ROM in THA. METHODS The incidence of the postoperative FT was evaluated on 40 computed tomography scans after cementless THA. With the help of a three-dimensional computer model of the hip, we then systematically analyzed the effects of FT on femoral antetorsion and its influence on calculations for a ROM maximized and impingement-free compliant stem/cup orientation. RESULTS The mean postoperative FT on CT scans was 5.7° ± 1.8°. In all tests, FT significantly influenced the antetorsion values. Re-calculating the compliant component positions according to the concept of combined anteversion with and without the influence of FT revealed that the zone of compliance could differ by more than 200%. For a 7° change in FT, the impingement-free cup position differed by 4° for inclination when the same antetorsion was used. CONCLUSIONS A range-of-motion optimized cup position in THA cannot be calculated based on antetorsion values alone. The FT has a significant impact on recommended cup positions within the concept of "femur first" or "combined anteversion". Ignoring FT may pose an increased risk of impingement as well as dislocation.
منابع مشابه
استئوتومی انتهای فوقانی ران برای درمان استئوآرتریت مفصل ران
During the past 20 years, poximal femoral osteotomy has been forgotten because most orthopedic surgeon believed that total hip arthroplasty is the only treatment method for hip joint osteoarthritis. The disadvatages of proximal femoral osteotomy include: Uncertain results, prolonged rehabilitation time after surgery, little improvement in joint ROM and according tosome.euthors difficult subsequ...
متن کاملFactors affecting bony impingement in hip arthroplasty.
Computer modeling of 10 patients' computed tomographic scans was used to study the variables affecting hip arthroplasty range of motion before bony impingement (ROMBI) including acetabular offset and height, femoral offset, height and anteversion, and osteophyte removal. The ROMBI was compared with the ROM before component impingement and the native hip ROM. The ROMBI decreased with decreased t...
متن کاملIn-Hospital Outcomes after Hemiarthroplasty versus Total Hip Arthroplasty for Isolated Femoral Neck Fractures
Background: Previous studies suggest total hip arthroplasty may have some benefits compared to hemi-arthroplasty for displaced intracapsular femoral neck fractures in patients more than 60 years of age. The primary research question of our study was whether in-hospital adverse events, post-operative length of stay (LOS) and mortality in patients 60 year of age or older differed between tot...
متن کاملEstablishing a range of motion boundary for total hip arthroplasty.
Range of motion of the hip joint is a major contributor to dislocation post total hip replacement. Impingement is often treated as a surrogate for dislocation and occurs--prosthetically--when the neck of the femoral component contacts with the rim of the pelvic acetabular cup. This impingement is caused by movement of the leg during activities of daily living. This article analyses hip joint ra...
متن کاملChallenges of Plate Fixation for Vancouver Type-C Fractures after a Well-Fixed Hip Arthroplasty Femoral Stem
The fixation of distal femoral fractures (Vancouver type-C fractures) following a well-fixed hip arthroplasty femoral stem has become a challenging issue for orthopedic surgeons due to the inter-prosthetic biomechanical effects such as negative, positive, and torsional strain. Surgeons have applied a range of constructs to overcome these difficulties. To minimize the risk of inter-prosthetic fr...
متن کامل