Assessment of liver viscoelasticity using multifrequency MR elastography.

نویسندگان

  • Patrick Asbach
  • Dieter Klatt
  • Uwe Hamhaber
  • Jürgen Braun
  • Rajan Somasundaram
  • Bernd Hamm
  • Ingolf Sack
چکیده

MR elastography (MRE) allows the noninvasive assessment of the viscoelastic properties of human organs based on the organ response to oscillatory shear stress. Shear waves of a given frequency are mechanically introduced and the propagation is imaged by applying motion-sensitive gradients. An experiment was set up that introduces multifrequency shear waves combined with broadband motion sensitization to extend the dynamic range of MRE from one given frequency to, in this study, four different frequencies. With this approach, multiple wave images corresponding to the four driving frequencies are simultaneously acquired and can be evaluated with regard to the dispersion of the complex modulus over the respective frequency. A viscoelastic model based on two shear moduli and one viscosity parameter was used to reproduce the experimental wave speed and wave damping dispersion. The technique was applied in eight healthy volunteers and eight patients with biopsy-proven high-grade liver fibrosis (grade 3-4). Fibrotic liver had a significantly higher (P < 0.01) viscosity (14.4 +/- 6.6 Pa x s) and elastic moduli (2.91 +/- 0.84 kPa; 4.83 +/- 1.77 kPa) than the viscosity (7.3 +/- 2.3 Pa x s) and elastic moduli (1.16 +/- 0.28 kPa; 1.97 +/- 0.30 kPa) of normal volunteers. Multifrequency MRE is well suited for the noninvasive differentiation of normal and fibrotic liver as it allows the measurement of rheologic material properties.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

MR elastography of the liver and the spleen using a piezoelectric driver, single-shot wave-field acquisition, and multifrequency dual parameter reconstruction.

PURPOSE Viscoelastic properties of the liver are sensitive to fibrosis. This study proposes several modifications to existing magnetic resonance elastography (MRE) techniques to improve the accuracy of abdominal MRE. METHODS The proposed method comprises the following steps: (i) wave generation by a nonmagnetic, piezoelectric driver suitable for integration into the patient table, (ii) fast s...

متن کامل

In Vivo Abdominal Magnetic Resonance Elastography for the Assessment of Portal Hypertension Before and After Transjugular Intrahepatic Portosystemic Shunt Implantation: Erratum.

OBJECTIVE The objective of this study was to investigate the correlation between hepatic venous pressure gradient (HVPG) and in vivo viscoelasticity of the liver and spleen before and after transjugular intrahepatic portosystemic shunt (TIPS) implantation. MATERIALS AND METHODS Ten patients with portal hypertension were examined twice by 3-dimensional multifrequency magnetic resonance elastog...

متن کامل

Multifrequency inversion in magnetic resonance elastography.

Time-harmonic shear wave elastography is capable of measuring viscoelastic parameters in living tissue. However, finite tissue boundaries and waveguide effects give rise to wave interferences which are not accounted for by standard elasticity reconstruction methods. Furthermore, the viscoelasticity of tissue causes dispersion of the complex shear modulus, rendering the recovered moduli frequenc...

متن کامل

In vivo MR elastography of liver: Comparison to oscillatory rheometer studies of tissue specimen

Introduction: Magnetic Resonance Elastography (MRE) is capable to measure the mechanical properties of living tissue by externally introduced shear vibrations and phase contrast MRI [1]. In multifrequency MRE the complex shear modulus G*(ω) of biological tissue is measured at various mechanical vibration frequencies simultaneously. Viscoelastic tissue parameters can then be calculated by fittin...

متن کامل

Viscoelastic Parameters for Quantifying Liver Fibrosis: Three-Dimensional Multifrequency MR Elastography Study on Thin Liver Rat Slices

OBJECTIVE To assess in a high-resolution model of thin liver rat slices which viscoelastic parameter at three-dimensional multifrequency MR elastography has the best diagnostic performance for quantifying liver fibrosis. MATERIALS AND METHODS The study was approved by the ethics committee for animal care of our institution. Eight normal rats and 42 rats with carbon tetrachloride induced liver...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Magnetic resonance in medicine

دوره 60 2  شماره 

صفحات  -

تاریخ انتشار 2008