Ideal spatial radiotherapy dose distributions subject to positional uncertainties.
نویسندگان
چکیده
In radiotherapy a common method used to compensate for patient setup error and organ motion is to enlarge the clinical target volume (CTV) by a 'margin' to produce a 'planning target volume' (PTV). Using weighted power loss functions as a measure of performance for a treatment plan, a simple method can be developed to calculate the ideal spatial dose distribution (one that minimizes expected loss) when there is uncertainty. The spatial dose distribution is assumed to be invariant to the displacement of the internal structures and the whole patient. The results provide qualitative insights into the suitability of using a margin at all, and (if one is to be used) how to select a 'good' margin size. The common practice of raising the power parameters in the treatment loss function, in order to enforce target dose requirements, is shown to be potentially counter-productive. These results offer insights into desirable dose distributions and could be used, in conjunction with well-established inverse radiotherapy planning techniques, to produce dose distributions that are robust against uncertainties.
منابع مشابه
Positional changes in parotid glands during head and neck radiation therapy
Introduction: Xerostomia is the most common complication due to radiation–induced damage to salivary glands in head and neck cancer radiotherapy and it reduces quality of life. Parotid glands are main glands which they are account for secretion of stimulated saliva. Studies have demonstrated that mean tolerance parotid’s radiation dose under 26-30 Gy result in an increase in t...
متن کاملDosimetric Effects of Rotational Setup Error in Volumetric Modulated Arc Radiotherapy on Brain Tumor Patients
Introduction: This study examined the dosimetric effects based on the rotational setup error to correct patient setup errors occur during volumetric modulated arc radiotherapy (VMAT) for brain tumor patients. Material and Methods: This study included 1129 cases of cone beam computed tomography (CBCT) images obtained from 46 brain tumor patients, who experienced VMAT and used the 6DoF (degree o...
متن کاملEffect of Tissue Composition on Dose Distribution in Electron Beam Radiotherapy
Objective: The aim of this study is to evaluate the effect of tissue composition on dose distribution in electron beam radiotherapy.Methods: A Siemens Primus linear accelerator and a phantom were simulated using MCNPX Monte Carlo code. In a homogeneous cylindrical phantom, six types of soft tissue and three types of tissue-equivalent materials were investigated. The tissues included muscle (ske...
متن کاملComparison of Electron-Beam Dose Distributions in a Heterogeneous Phantom Obtained Using Radiochromic Film Dosimetry and Monte Carlo Simulation
Introduction: Nowadays new radiochromic films have an essential role in radiotherapy dosimetry. Properties such as high sensitivity, good reproducibility, high spatial resolution, easy readout and portability have made them attractive for dosimetry, especially in high-dose-gradient regions. Material and Methods: In this study, electron-beam dose distributions in homogenous and heterogeneous pha...
متن کاملRectal wall dose estimation in intracavitary brachytherapy: A preliminary comparison of an in-house rectal wire versus ICRU 38 recommendations
Background: In intracavitary brachytherapy for gynecological cancers, various techniques are used to locate the anterior rectal wall nearest to the sources but there is no consensus on the best method to do so. This study aimed to compare a technique used routinely in some centers that employs a wire marker to locate the position of the maximum rectal dose point, versus the method recommended b...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Physics in medicine and biology
دوره 51 24 شماره
صفحات -
تاریخ انتشار 2006