Accuracy of optical coherence tomography (OCT) in pachymetry for glaucoma patients

نویسندگان

  • Marcelo Ayala
  • Robert Strandås
چکیده

BACKGROUND Central corneal thickness (CCT) measurement has become an important test in the diagnosis and management of glaucoma. Currently, ultrasound corneal thickness measurement (pachymetry) is the most frequently used clinical technique and the gold standard to assess CCT. Newer instruments are currently available including the optical coherence tomography (OCT) instrument. The aim of the present study was therefore to evaluate the accuracy of the CCT measurements performed by three different observers, both with the OCT and ultrasound pachymetry (USP), in patients suffering from glaucoma. METHODS Patients who had been previously diagnosed with glaucoma participated in this cross-sectional study. Glaucoma was defined as patients who had at least two repeatable Humphrey visual fields showing glaucoma damage using the software 24-2, and with the optic nerve showing typical glaucoma damage. The patients CCTs were measured with OCT and USP by three different examiners. RESULTS Seventy eyes of 35 patients were included. The average age was 74 ± standard deviation (SD) 10.88, the average pachymetry value with OCT was 536 ± 29 μm, and the average pachymetry with USP was 532 ± 32 μm. The differences between OCT and USP were not significant (t-test, p = 0.32). The intraclass correlation coefficients were, for OCT, 0.99 [confidence interval (CI): 0.98-0.996], and for USP, 0.97 (CI: 0.95-0.98). CONCLUSIONS Agreement among the three observers using OCT or USP for pachymetry measurements was good. OCT might be used as an alternative method for pachymetry in glaucoma patients.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Development of an Advanced Optical Coherence Tomography System for Radiation Dosimetry

Introduction: According to the literature, optical coherence tomography (OCT) can be used measure radiation absorbed dose. This study was carried out to design a computed tomography system for the calculation of absorbed dose and optimization of dose delivery in radiotherapy using gel dosimeters. Material and Methods: An advanced charge-coupled device based OCT system was developed in laborator...

متن کامل

Peripapillary Intrachoroidal Cavitation and Optic Pit in a Case of High Myopia and Glaucoma

Purpose: To report a case of peripapillary intrachoroidal cavitation (choroidal schisis) and optic pit in a case of high myopia and open-angle glaucoma. Case report: A 30-year-old high myopic man was referred to our clinic for presumed peripapillary choroidal tumors. In funduscopy, there were two yellow-orange and slightly elevated peripapillary lesions in both eyes with indistinct margins. A s...

متن کامل

[Anterior segment optical coherence tomography in glaucoma].

In recent years, the rapid development of diagnostic optic devices has generated optical coherence tomography (OCT) as a new, non-invasive diagnostic method. With technical progress of the infrared spectrum at 1,310 nm, OCT of the anterior segment also became feasible. With anterior segment OCT different examinations which so far were ruled out by ultrasound in contact manner could be executed ...

متن کامل

Optical Coherence Tomography and Corpus Callosum Index in Cognitive Assessment of Multiple Sclerosis Patients

Background: Multiple Sclerosis (MS) is a neurodegenerative disease of central nervous system. Different approaches have been developed to study MS progression and cognitive dysfunction as the major symptom of the disease. The current study compared Optical Coherence Tomography (OCT) and Corpus Callosum Index (CCI) for the early evaluation of cognitive dysfunction in MS patients.  Objectives: T...

متن کامل

Accuracy of Alcon WaveLight® EX500 optical pachymetry during LASIK

PURPOSE To study the accuracy and reliability of optical pachymetry using the Alcon WaveLight EX500 during laser-assisted in situ keratomileusis (LASIK). MATERIALS AND METHODS This was a retrospective chart review of 90 eyes from 45 patients who had undergone LASIK (mean age 35.2±8.2 years; 19 males, 26 females). The WaveLight FS200 femtosecond laser was programmed to cut LASIK flaps at a des...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 15  شماره 

صفحات  -

تاریخ انتشار 2015