Potential and Electric Field Characteristics of Broken Porcelain Insulator

نویسندگان

  • H. Rosli
  • N. A. Othman
  • N. A. M. Jamail
  • M. N. Ismail
چکیده

Received Jul 10, 2017 Revised Oct 14, 2017 Accepted Oct 26, 2017 Overhead line insulators can be damaged for various reasons during their service life. Porcelain or glass insulators once damaged can affect the reliability of power system networks. This paper presents the study of voltage and electric characteristics along the surface of a broken porcelain insulator located in a string of 10 unit insulators. Three models of broken porcelain insulators were being proposed and the analysis results on voltage and electric characteristics were individually collected. The broken porcelain insulator with the most significant effect were then being investigated in the strings of 10 unit insulators. The finite element software of Quickfield was used to analyze the voltage and electric characteristics. Form the presented results, it is proven that the single porcelain insulators with broken shed at the nearest to the electrode terminal gave the most significant effect of voltage and electric field distribution pattern along the creepage distance. However, when this type of broken insulator was included in a string of 10 unit insulators, maximum average value of voltage achieved once the broken insulator was located at the HV terminal. Meanwhile, the highest electric field strength was recorded when the broken insulator was located in the middle of the string. Keyword:

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effects of Disc Insulator Type and Corona Ring on Electric Field and Voltage Distribution over 230-kV Insulator String by Numerical Method

Insulator strings with several material and profiles are very common in overhead transmission lines. However, the electric field and voltage distribution of insulator string is uneven which may easily lead to corona, insulators’ surface deterioration and even flashover. So the calculation of the electric field and voltage distribution along them is a very important factor in the operation time....

متن کامل

Simplification Study of FE Model for 1000kV AC Transmission Line Insulator String Voltage and Grading Ring Surface Electric Field Distribution Calculation

The finite element model of the 1000kV Ultra High Voltage (UHV) AC transmission line porcelain insulator string voltage distribution and grading ring surface electric field distribution calculation has the characteristics of large size, complicated structure and various mediums. To insure the accuracy, related influencing factors should be considered to simplify the model reasonably for improvi...

متن کامل

Impact of Pollution Location on Time and Frequency Characteristics of Leakage Current of Porcelain Insulator String under Different Humidity and Contamination Severity

One of the important factors influencing outdoor insulators performance is pollution phenomenon. The pollution, especially during humidity condition, reduces superficial resistance of insulator and lead to a flow of Leakage Currents (LC) on the insulator surface, which may result in total flashover. The LC characteristics are affected by parameters such as nature and severity of pollution. Loca...

متن کامل

Simulation of Potential and Electric Field across Faulty Ceramic Disc Insulator String

Ceramic/Porcelain insulators are widely used in power transmission lines to provide mechanical support for High voltage conductors in addition to withstand electrical stresses. As a result of lightning, switching or temporary over voltages that could initiate flashover under worst weather conditions, and to operate within interference limits. Given that the useful life in service of the individ...

متن کامل

Simulation of Potential and Electric Field across Faulty Ceramic Disc Insulator String

Ceramic/Porcelain insulators are widely used in power transmission lines to provide mechanical support for High voltage conductors in addition to withstand electrical stresses. As a result of lightning, switching or temporary over voltages that could initiate flashover under worst weather conditions, and to operate within interference limits. Given that the useful life in service of the individ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2017