Quality Assurance of IMRT delivery systems – Varian
نویسنده
چکیده
Introduction Intensity modulated radiation therapy (IMRT) provides the means for improved treatment for a wide variety of cancers. Piggybacked onto 3DCRT and MLC technologies, IMRT has developed quickly, but will undoubtedly see improvements in core hardware and software as well as in peripheral applications such as record and verify, gating, etc. At the core, individual treatment centers should expect a learning curve for understanding novel treatment planning and quality assurance (QA) issues. The urge to implement IMRT at individual therapy centers should be tempered while these issues come into focus and are addressed at each center. This presentation will discuss issues affecting dose calculation and delivery, i.e., the commissioning as well as routine QA of the Varian MLC, to provide SegmentedMLC (step and shoot) and DynamicMLC (sliding window) treatments. The QA program at MSKCC has evolved over seven years of clinical IMRT experience using DMLC.
منابع مشابه
Comparison of four commercial devices for RapidArc and sliding window IMRT QA
For intensity-modulated radiation therapy, evaluation of the measured dose against the treatment planning calculated dose is essential in the context of patient-specific quality assurance. The complexity of volumetric arc radiotherapy delivery attributed to its dynamic and synchronization nature require new methods and potentially new tools for the quality assurance of such techniques. In the p...
متن کاملDosimetric and qualitative analysis of kinetic properties of millennium 80 multileaf collimator system for dynamic intensity modulated radiotherapy treatments.
The aim of this paper is to analyze the positional accuracy, kinetic properties of the dynamic multileaf collimator (MLC) and dosimetric evaluation of fractional dose delivery for the intensity modulated radiotherapy (IMRT) for step and shoot and sliding window (dynamic) techniques of Varian multileaf collimator millennium 80. Various quality assurance tests such as accuracy in leaf positioning...
متن کاملPhysical and Dosimetric Aspect of Euromechanics Add-on Multileaf Collimator on Varian Clinac 2100 C/D
Background:Â Before treatment planning and dose delivery, quality assurance of multi-leaf collimator (MLC) has an important role in intensity-modulated radiation therapy (IMRT) due to the creation of multiple segments from optimization process.Objective: The purpose of this study is to assess the quality control of MLC leaves using EBT3 Gafchromic films.Material and Methods: Leaf Position accur...
متن کاملPhantoms / QA A quality assurance method that utilizes 3 D dosimetry and facilitates clinical interpretation
A quality assurance method that utilizes 3D dosimetry and facilitates clinical interpretation Oldham Mark; Thomas Andrew; O'Daniel Jennifer; Juang Titania; Ibbott Geoffrey; Adamovics John; Kirkpatrick John P International journal of radiation oncology, biology, physics (2012), 84(2), 540-6. PURPOSE: To demonstrate a new three-dimensional (3D) quality assurance (QA) method that provides comprehe...
متن کاملDesign of an Anthropomorphic Intensity Modulated Radiation Therapy Quality Assurance Phantom
The dynamic nature of IMRT delivery poses unique problems relating to the accurate and reproducible quality assurance of dose delivery. The usefulness of point detectors is limited to static fields and regions within low dose-gradients for treatment verification. However, dose distributions generated in intensity modulated radiation therapy (IMRT) often have complex shapes with high dose gradie...
متن کامل