Efficacy of vaporized hydrogen peroxide against exotic animal viruses.

نویسندگان

  • R A Heckert
  • M Best
  • L T Jordan
  • G C Dulac
  • D L Eddington
  • W G Sterritt
چکیده

The efficacy of vapor-phase hydrogen peroxide in a pass-through box for the decontamination of equipment and inanimate materials potentially contaminated with exotic animal viruses was evaluated. Tests were conducted with a variety of viral agents, which included representatives of several virus families (Orthomyxoviridae, Reoviridae, Flaviviridae, Paramyxoviridae, Herpesviridae, Picornaviridae, Caliciviridae, and Rhabdoviridae) from both avian and mammalian species, with particular emphasis on animal viruses exotic to Canada. The effects of the gas on a variety of laboratory equipment were also studied. Virus suspensions in cell culture media, egg fluid, or blood were dried onto glass and stainless steel. Virus viability was assessed after exposure to vaporphase hydrogen peroxide for 30 min. For all viruses tested and under all conditions (except one), the decontamination process reduced the virus titer to 0 embryo-lethal doses for the avian viruses (avian influenza and Newcastle disease viruses) or less than 10 tissue culture infective doses for the mammalian viruses (African swine fever, bluetongue, hog cholera, pseudorabies, swine vesicular disease, vesicular exanthema, and vesicular stomatitis viruses). The laboratory equipment exposed to the gas appeared to suffer no adverse effects. Vaporphase hydrogen peroxide decontamination can be recommended as a safe and efficacious way of removing potentially virus-contaminated objects from biocontainment level III laboratories in which exotic animal disease virus agents are handled.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Vaporized Peracetic Acid (vpa) Sterilization

M in ne ap ol is , M N 5 54 47 VAPORIZED PERACETIC ACID (VPA) STERILIZATION Peracetic Acid as a Biocide REVOXTM sterilization technology uses a room temperature vapor composed of three active compounds; hydrogen peroxide (H2O2), acetic acid and peracetic acid (PAA). PAA is formed by the reaction of acetic acid and H2O2 with the addition of a catalyst; these compounds exist in equilibrium and th...

متن کامل

Virucidal efficacy of a sonicated hydrogen peroxide system (trophon® EPR) following European and German test methods

Aim: The virucidal efficacy of an automated ultrasound probe disinfector (trophon® EPR) was evaluated in a three step procedure according to European and German test methods. This system uses sonicated hydrogen peroxide mist (35%) at elevated temperature (50°C) in a closed chamber with control of all parameters within a 7 minute cycle. Methods: In the first step of examination, the peroxide sol...

متن کامل

Effectiveness of hydrogen peroxide and electron-beam irradiation treatment for removal and inactivation of viruses in equine-derived xenografts.

Bone grafting is a common procedure for bone reconstruction in dentistry, orthopedics, and neurosurgery. A wide range of grafts are currently used, and xenografts are regarded as an interesting alternative to autogenous bone because all mammals share the same bone mineral component composition and morphology. Antigens must be eliminated from bone grafts derived from animal tissues in order to m...

متن کامل

Efficacy of "green" cleaning products with respect to common respiratory viruses and mold growth.

Some disinfectants have been demonstrated to be effective against surface mold growth and/or viruses responsible for the spread of common respiratory infections. Antimicrobial efficacy of green cleaning products has generally not been established in these areas. In this survey, the author found that out of 27 products approved by Green Seal as hard surface cleaners, 26 do not claim antimicrobia...

متن کامل

Low-temperature decontamination with hydrogen peroxide or chlorine dioxide for space applications.

The currently used microbial decontamination method for spacecraft and components uses dry-heat microbial reduction at temperatures of >110°C for extended periods to prevent the contamination of extraplanetary destinations. This process is effective and reproducible, but it is also long and costly and precludes the use of heat-labile materials. The need for an alternative to dry-heat microbial ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Applied and environmental microbiology

دوره 63 10  شماره 

صفحات  -

تاریخ انتشار 1997