WFC3 Ambient Testing: UVIS Dark Current Rate

نویسنده

  • B. Hilbert
چکیده

Ground testing of WFC3 under ambient conditions during April of 2007 was performed in order to prepare for upcoming thermal vacuum testing. As a part of this ambient testing, the dark current rate of the spare UVIS package (UVIS build 2) was measured while the CCD was operating at a temperature of -54oC. This temperature is significantly higher than the nominal operating temperature of -83oC, leading to a higher overall dark current rate, as well as a larger population in the high dark current tail of the distribution. Measured dark current values at the peak of the distributions corresponding to the 4 amplifiers were 9.0 – 13.9 e-/pix/hour.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

WFC3 UVIS High-resolution Imaging Performance

The sharp and stable point spread function of HST and WFC3 allows for the detection of stellar companions at small offsets from target stars. Deep images obtained through six UVIS filters are used to assess this ability to detect faint companions of brighter targets. Analogous capabilities from the ground make use of Adaptive Optics and Speckle imaging. We contrast the capabilities of HST/WFC3 ...

متن کامل

WFC3 Thermal Vacuum Testing: UVIS Crosstalk

The integrated WFC3 instrument recently underwent testing under thermal vacuum (TV) conditions in the GSFC SES (Goddard Space Flight Center Space Environment Simulator). This report summarizes the behavior of the UVIS channel crosstalk features seen in the TV data as compared to the behavior seen in previous data taken under ambient conditions in early 2004 and provides an update on the hardwar...

متن کامل

WFC3 TV3 Testing: System Throughput on the UVIS Build 1’ Detector

The UVIS flight detector (UVIS build 1’) was installed in WFC3 prior to its third and final campaign of thermal vacuum ground testing. We performed testing of the end-to-end system throughput on the UVIS channel, and found that it performs near or better than expectations at most wavelengths. However, the measured throughput is significantly different than that measured for this detector in the...

متن کامل

WFC3 Flight Detector Alignment Characterization in Thermal-Vacuum Test #1

We have performed an initial assessment of the alignment status of the UVIS-1and IR-2 flight detectors as mounted in WFC3 during the first instrument-level thermal-vac test. Both detectors are found to be aligned out of tolerance, indicating errors in the transfer of surrogate alignment information to the flight articles. Measurements made at various times through the thermal vac test, with the...

متن کامل

WFC3 TV3 Testing: Quantum Yield of the UVIS CCDs

We measure the quantum yield (technically, the true quantum yield plus the Fano factor) from a large set of monochromatic narrowband post-TV3 flatfields taken with WFC3 in the UVIS channel. Our analysis results show that the quantum yield is ∼30% less than predicted, in good agreement with earlier results based on a small set of broadband UV filters (Baggett 2008).

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2007