The application of a compact MR - compatible SPECT system for small animal SPECT / MR imaging and tracer kinetics studies
نویسندگان
چکیده
BODY: Objectives : A new F-18 agent for PET myocardial perfusion imaging (BMS747158) has been shown to have excellent image quality in a Phase I clinical trial. In a subgroup of patients undergoing imaging with this agent in a Phase II clinical trial, we assessed if dual gated perfusion study is feasible and leads to improved image quality. We generated motion free perfusion images by combining amplitude based respiratory gating and the “Motion Frozen” (MF) processing technique (JNM 2004:45:1128-34) which eliminates cardiac motion in static images. Methods : In 6 patients, PET imaging was performed in dual -cardiac and respiratorymode on a 4-ring Siemens Biograph-64. Static and 8-bin ECG-gated images using either full 5 minutes of the acquisition or a narrow range of breathing amplitude around end-expiration level keeping 30% of a 10-minute acquisition (RespiG) were reconstructed with HD●PET. MF was then applied to the gated datasets. We computed the wall/cavity contrast and contrast-to-noise ratio (CNR) to assess image quality. Wall thickness, motion, thickening and ejection fraction (EF) were also estimated with automatic quantification. Results : On average, the contrast was the same with HD●PET (9.1±3.2) and RespiG-HD●PET (9.2±2.4) but was significantly improved with MF:HD●PET (10.7±3.6) and further with MF:RespiG-HD●PET (13.0±4.8, p<0.05). CNR was 16.9±10.4 with HD●PET, 20.1±13.3 with RespiG-HD●PET, 32.6±12.2 with MF:HD●PET and 28.7±4.0 MF:RespiG-HD●PET. The wall thickness was significantly decreased with MF:RespiG-HD●PET (10.8±1.7mm) compared to HD●PET (13.6±2.1mm), RespiG-HD●PET (12.5±2.3mm) and MF:HD●PET (12.0±1.8)(all p<0.05). EF, motion and thickening did not show any significant change between any processing method. Conclusions : Dual gated perfusion imaging is feasible with a new F-18 agent and shows significantly improved image resolution, contrast and contrast-to-noise when combined with Motion Frozen processing. (no table selected) 69-year old female patient recruited in Phase II clinical trial for a new F-18 myocardial perfusion agent (BMS747158) and acquired in dual -cardiac and respiratorymode. Short axis, vertical and horizontal axis views of images reconstructed with, from top to bottom, HD●PET, respiratory gating + HD●PET, Motion Frozen + HD●PET and Respiratory gating + Motion Frozen + HD●PET.
منابع مشابه
Evaluation of the performance of parallel-hole collimator for high resolution small animal SPECT: A Monte Carlo study
Introduction: Image quality and accuracy of in vivo activity quantification in SPECT are affected by collimator penetration and scatter components, especially in high energy imaging. These phenomena highly depend on the collimator characteristic and photon energy. The presence of penetrated and scattered photons from collimator in SPECT images degrades spatial resolution, contr...
متن کاملMRC-SPECT: A sub-500 μm resolution MR-compatible SPECT system for simultaneous dual-modality study of small animals.
In this paper, we will report the development of an ultrahigh resolution MR-compatible SPECT system that can be operated inside a pre-existing clinical MR scanner for simultaneous dual-modality imaging of small animals. This system is constructed with 40 small-pixel CdTe detector modules assembled in a fully stationary ring SPECT geometry. We have experimentally demonstrated that this system is...
متن کاملMRC-SPECT-DF: an MR-Compatible SPECT system with Dual-FOV collimation design for microscopic SPECT imaging
University of Illinois, USA We will report the design and performance of a MR-compatible SPECT system that utilizes a dual-FOV aperture design for microscopic SPECT imaging of small animals inside an pre-existing MR scanner. The MRC-SPECT-DF system consists of a full ring of high resolution CdTe detectors and an aperture that consists of dual-FOV aperture system design that has two sets of aper...
متن کاملEvaluation of radiolabeled streptokinase for thrombosis imaging
Introduction: Cardiovascular disease is the major cause of morbidity and mortality in developing and developed countries. Rapid diagnosis of the thrombosis can be an essential step in management of the stroke. Methods: In this work a recently developed radiolabeled streptokinase (STP) tracer was evaluated in an animal thrombotic model using SPECT imaging and biodis...
متن کاملPreparation and Biodistribution of [67Ga]-labeled- oxytocin for SPECT purposes
Background: Oxytocin (OT) is a paracrine hormone with various biological activities and many sex organs in both sexes, as well as many tumor cells have shown to have related receptors. In this study the development of a receptor imaging tracer for possible tumor imaging has been described. Materials and Methods: OT was successively labeled with [67Ga]-gallium chloride after conjugation with fre...
متن کاملPreclinical studies of 166Ho-chitosan for treatment of hepatocellular carcinoma
Introduction: Recently, due to the special characteristics of 166Ho and chitosan, 166Ho-chitosan complex was developed for treatment of tumors such as hepatocellular carcinoma. This complex has been lately prepared with high radiochemical purity in our lab. The preclinical studies of the complex however should be performed to evaluate the tracer concentration in target and...
متن کامل