Continuous-wave Doppler velocities and gradients across fixed tunnel obstructions: studies in vitro and in vivo.

نویسندگان

  • A P Yoganathan
  • L M Valdes-Cruz
  • J Schmidt-Dohna
  • A Jimoh
  • C Berry
  • T Tamura
  • D J Sahn
چکیده

The simplified Bernoulli relationship appears to be quite accurate for predicting gradients across discrete valvular obstructions. Controversy exists about how accurately it predicts the severity of disease in longer segment obstructions. In this study we constructed a pulsatile model of subvalvular pulmonary stensosis in vitro to study nine custom-made subvalvular tunnels 2, 4, and 7 mm in length with flow cross sections of 0.5 to 1.5 cm2 and with the stenotic segment proximal to a nonstenotic bioprosthetic valve, and a pulsatile model in vitro of a 16 mm long tunnel-like ventricular septal defect (VSD) of varying cross-sectional area (0.20 to 0.64 cm2). We also compared the observations in vitro with those in an open-chest dog preparation with a tunnel-like interventricular communication. In the subpulmonic stenosis model, for each individual tunnel, 10 instantaneous peak gradients between 15 to 105 mm Hg were available. The pressure gradients across the tunnel alone, measured in the subvalvular area, were consistently higher than the measured gradients across the tunnel plus valve, suggesting some relaminarization of flow (i.e., a decrease in velocity) and pressure recovery (i.e., an increase in pressure) distal to the obstruction. Continuous-wave Doppler velocities across the 4 and 7 mm tunnels for the highest gradients were slightly lower than for the 2 mm tunnel at the same gradients, and it was only for the 0.5 cm2 cross section, 4 and 7 mm tunnels that there was a suggestion of minor viscous energy loss. For all the subvalvular tunnels studied, the Bernoulli relationship accurately predicted the results of the pressure drop across the tunnel only, while the gradient across tunnel plus valve was consistently lower. For the VSD tunnel model in vitro, the Doppler-derived gradients were approximately 40% higher than the measured gradients. The findings for the subvalvular and VSD tunnels in vitro and similar findings in the open-chest dogs with VSD suggest that relaminarization of flow and recovery of pressure occurred distal to the tunnel orifice, whereas continuous-wave Doppler findings correlate with the highest instantaneous gradients measured in the lowest pressure areas at the vena contracta of the tunnel.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

DOPPLER ECHOCARDIOGRAPHY Continuous - wave Doppler velocities and gradients across fixed tunnel obstructions : studies in vitro and in vivo

The simplified Bernoulli relationship appears to be quite accurate for predicting gradients across discrete valvular obstructions. Controversy exists about how accurately it predicts the severity of disease in longer segment obstructions. In this study we constructed a pulsatile model of subvalvular pulmonary stensosis in vitro to study nine custom-made subvalvular tunnels 2, 4, and 7 mm in len...

متن کامل

The accuracy of Doppler ultrasound measurement of pressure gradients across irregular, dual, and tunnellike obstructions to blood flow.

The accuracy of Doppler-estimated pressure gradients in the setting of irregular, multiple, and tunnellike stenoses was investigated. An in vitro model of the left ventricular outflow tract was designed to allow pulsatile flow of red cells in saline across valve orifices from 0.01 to 2.5 cm2. Simultaneous pressure gradients were estimated by both Doppler and direct-pressure manometer techniques...

متن کامل

Studies in vitro of the relationship between ultrasound and laser Doppler velocimetry and applicability to the simplified Bernoulli relationship.

While there has been wide general acceptance of Doppler methods that use the simplified Bernoulii relationship to estimate pressure gradients across stenotic orifices, there is still ongoing controversy related to potential sources of error in the method. In this study we tested accuracy o ultrasound Doppler measurements of flow velocity when compared with the gold standard of laser light Doppl...

متن کامل

Continuous wave Doppler echocardiographic measurement of prosthetic valve gradients. A simultaneous Doppler-catheter correlative study.

Studies correlating prosthetic valve gradients determined by continuous wave Doppler echocardiography with gradients obtained by cardiac catheterization have, to date, been limited to patients with mitral and tricuspid prostheses or have compared nonsimultaneous measurements. Simultaneous Doppler and catheter pressure gradients in 36 patients (mean age, 63 +/- 13 years) with 42 prosthetic valve...

متن کامل

Normal pulsed wave Doppler echocardiographic parameters of Turkmen horses of Iran

Turkmen horse is one of the oldest and purest breeds in the world, but there is no information on Doppler echocardiographic parameters in this horse. In the present study, pulsed-wave (PW) Doppler echocardiography was performed on 42 clinically normal 3- to 15-year-old racing Turkmen horses. No cardiac disease was detected with two-dimensional (2-D) real-time, M-mode, and colour flow mapping. D...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 76 3  شماره 

صفحات  -

تاریخ انتشار 1987