Feasibility of a fast method for B1-inhomogeneity correction for FSPGR sequences.

نویسندگان

  • Jeroen J N van Schie
  • Cristina Lavini
  • Lucas J van Vliet
  • Frans M Vos
چکیده

The Fast Spoiled Gradient Echo (FSPGR) sequence is often used in MRI to create T1-weighted images. The signal intensity generated by this sequence depends on the applied flip angle. Knowing the correct flip angle is essential for the determination of T1-maps by means of an FSPGR based Variable Flip Angle (VFA) approach. Also, quantitatively determining the concentration of contrast agent in case of Dynamic Contrast Enhanced MRI (DCE-MRI) requires knowledge of the applied flip angle. In both cases, the B1-field (in)homogeneity significantly affects the results. In this paper, we present a new method to obtain both the T1-map and B1-inhomogeneity map using scans that can each be acquired within a breath-hold. We combine two short sequences for T1 quantification: Variable Flip Angle and Look-Locker (LL). The T1-maps obtained from the LL data were used to estimate the B1-inhomogeneity inherently present in the VFA data, which was then used to correct for the VFA method's inaccurate flip angles. This way, a reliable T1-map could be computed, which was validated using both in vitro and in vivo scans. The in vitro results show that the procedure yields a substantially smaller mean deviation in T1 from the T1 measurement's gold standard (the Inversion Recovery method), while the in vivo results show both a more accurate estimation of T1 and a reduction of the influence of the B1-inhomogeneity on the signal intensity.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Direct and Indirect Surface Coil Correction for Cardiac Perfusion MRI

Introduction Although the first-pass myocardial perfusion MRI has proven its effectiveness in the diagnosis of ischemic heart disease, this technique is still not routinely used. Certain technical difficulties prevent perfusion MRI from being added into the clinical workflow, including complex cardiac motion, limited imaging time, and B1-field inhomogeneity caused by non-uniform characteristics...

متن کامل

On the transmit field inhomogeneity correction of relaxation‐compensated amide and NOE CEST effects at 7 T

High field MRI is beneficial for chemical exchange saturation transfer (CEST) in terms of high SNR, CNR, and chemical shift dispersion. These advantages may, however, be counter-balanced by the increased transmit field inhomogeneity normally associated with high field MRI. The relatively high sensitivity of the CEST contrast to B1 inhomogeneity necessitates the development of correction methods...

متن کامل

Sparse spokes slice selective design for B1 inhomogeneity correction at 7T

Introduction: At high magnetic field strength, B1 inhomogeneity causes undesired effects of non-uniformity in SNR and contrast. For slice selective excitation, 3D RF pulse design proposed in [1,2,3], can be used to mitigate this B1 inhomogeneity effect. These designs are based on playing kz sinc “spokes” of different amplitude at a number of (kx,ky) locations around the k-space origin. The sinc...

متن کامل

Quantitative T(1)(ρ) imaging using phase cycling for B0 and B1 field inhomogeneity compensation.

T(1)(ρ) imaging is useful in a number of clinical applications. T(1)(ρ) preparation methods, however, are sensitive to non-uniformities of the B0 magnetic field and the B1 RF field. These common system imperfections can result in image artifacts and quantification errors in T(1)(ρ) imaging. We report on a phase-cycling method which can eliminate B1 RF inhomogeneity effects in T(1)(ρ) imaging. T...

متن کامل

A Feasibility Study of IMRT of Lung Cancer Using Gafchromic EBT3 Film

Background: Intensity modulated radiation therapy (IMRT) is an advanced method for delivery of three dimensional therapies, which provides optimal dose distribution with giving multiple nonuniform fluency to the patient. The complex dose distribution of IMRT should be checked to ensure that the accurate dose is delivered. Today, film dosimetry is a powerful tool for radiotherapy treatment Quali...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Magnetic resonance imaging

دوره 33 3  شماره 

صفحات  -

تاریخ انتشار 2015