Independent monitor unit calculation for intensity modulated radiotherapy using the MIMiC multileaf collimator.
نویسندگان
چکیده
A self-consistent monitor unit (MU) and isocenter point-dose calculation method has been developed that provides an independent verification of the MU for intensity modulated radiotherapy (IMRT) using the MIMiC (Nomos Corporation) multileaf collimator. The method takes into account two unique features of IMRT using the MIMiC: namely the gantry-dynamic arc delivery of intensity modulated photon beams and the slice-by-slice dose delivery for large tumor volumes. The method converts the nonuniform beam intensity planned at discrete gantry angles of 5 degrees or 10 degrees into conventional nonmodulated beam intensity apertures of elemental arc segments of 1 degree. This approach more closely simulates the actual gantry-dynamic arc delivery by MIMiC. Because each elemental arc segment is of uniform intensity, the MU calculation for an IMRT arc is made equivalent to a conventional arc with gantry-angle dependent beam apertures. The dose to the isocenter from each 1 degree elemental arc segment is calculated by using the Clarkson scatter summation technique based on measured tissue-maximum-ratio and output factors, independent of the dose calculation model used in the IMRT planning system. For treatments requiring multiple treatment slices, the MU for the arc at each treatment slice takes into account the MU, leakage and scatter doses from other slices. This is achieved by solving a set of coupled linear equations for the MUs of all involved treatment slices. All input dosimetry data for the independent MU/isocenter point-dose calculation are measured directly. Comparison of the MU and isocenter point dose calculated by the independent program to those calculated by the Corvus planning system and to direct measurements has shown good agreement with relative difference less than +/-3%. The program can be used as an independent initial MU verification for IMRT plans using the MIMiC multileaf collimators.
منابع مشابه
A simple theoretical verification of monitor unit calculation for intensity modulated beams using dynamic mini-multileaf collimation.
A spreadsheet based program is presented to perform an independent Monitor Unit (MU) calculation verification for the Quality Assurance (QA) of Intensity Modulated Radiation Therapy (IMRT) using Dynamic MultiLeaf Collimation (DMLC). The computed dose value is compared to the planned dose by calculating the percent dose difference per Intensity Modulated Beam (IMB) and absolute dose difference p...
متن کاملDesign, Simulation and Manufacture of a Multileaf Collimator to Confirm the Target Volumes in Intensity Modulated Radiation Therapy
Introduction: Intensity modulated radiation therapy (IMRT) is one of the cancer treatment methods. It is important to selectively aim at the target in this way, which can be performed using a multileaf collimator (MLC). Materials and Methods: In order to specifically irradiate the target volume in radiotherapy to reduce the patient absorbed dose, the use of multileaf collimator has been investi...
متن کاملOptimal Sequencing of Dynamic Multileaf Collimators
Dynamic multileaf collimator (DMLC)-intensity modulated radiation therapy (IMRT) is used to delivery intensity-modulated beams using an MLC, with the leaves in motion. DMLC-IMRT requires the conversion of a radiation fluence map into a leaf sequence file that controls the movement of the MLC while the beam is on. It is imperative that the fluence map delivered using the leaf sequence file be as...
متن کاملA new mathematical model for intensity matrix decomposition using multileaf collimator
Cancer is one of the major causes of death all over the globe and radiotherapy is considered one of its most effective treatment methods. Designing a radiotherapy treatment plan was done entirely manually in the past. RecentlyIntensity Modulated Radiation Therapy (IMRT) was introduced as a new technology with advanced medical equipmentin the recent years. IMRT provides the opportunity to delive...
متن کاملReducing the number of monitor units in multileaf collimator field segmentation.
Multileaf collimators (MLCs) are the prevailing tool for the realization of radiation fields in intensity modulated radiation therapy (IMRT). One step in the treatment planning is to determine a set of leaf positions realizing a certain intensity modulated radiation field. In this paper we suggest two extensions in the use of the MLC that lead to considerable savings in terms of monitor units, ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Medical physics
دوره 29 9 شماره
صفحات -
تاریخ انتشار 2002