Automatic method of analysis of OCT images in the assessment of the tooth enamel surface after orthodontic treatment with fixed braces

نویسندگان

  • Robert Koprowski
  • Monika Machoy
  • Krzysztof Woźniak
  • Zygmunt Wróbel
چکیده

INTRODUCTION Fixed orthodontic appliances, despite years of research and development, still raise a lot of controversy because of its potentially destructive influence on enamel. Therefore, it is necessary to quantitatively assess the condition and therein the thickness of tooth enamel in order to select the appropriate orthodontic bonding and debonding methodology as well as to assess the quality of enamel after treatment and clean-up procedure in order to choose the most advantageous course of treatment. One of the assessment methods is computed tomography where the measurement of enamel thickness and the 3D reconstruction of image sequences can be performed fully automatically. MATERIAL AND METHOD OCT images of 180 teeth were obtained from the Topcon 3D OCT-2000 camera. The images were obtained in vitro by performing sequentially 7 stages of treatment on all the teeth: before any interference into enamel, polishing with orthodontic paste, etching and application of a bonding system, orthodontic bracket bonding, orthodontic bracket removal, cleaning off adhesive residue. A dedicated method for the analysis and processing of images involving median filtering, mathematical morphology, binarization, polynomial approximation and the active contour method has been proposed. RESULTS The obtained results enable automatic measurement of tooth enamel thickness in 5 seconds using the Core i5 CPU M460 @ 2.5GHz 4GB RAM. For one patient, the proposed method of analysis confirms enamel thickness loss of 80 μm (from 730 ± 165 μm to 650 ± 129 μm) after polishing with paste, enamel thickness loss of 435 μm (from 730 ± 165 μm to 295 ± 55 μm) after etching and bonding resin application, growth of a layer having a thickness of 265 μm (from 295 ± 55 μm to 560 ± 98 μm after etching) which is the adhesive system. After removing an orthodontic bracket, the adhesive residue was 105 μm and after cleaning it off, the enamel thickness was 605 μm. The enamel thickness before and after the whole treatment decreased by about 125 μm. CONCLUSIONS This paper presents an automatic quantitative method for the assessment of tooth enamel thickness. This method has proven to be an effective diagnostic tool that allows evaluation of the surface and cross section of tooth enamel after orthodontic treatment with fixed thin-arched braces and proper selection of the methodology and course of treatment.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effects of Light-cured versus No-mix and Self-etch Primer Adhesives on Enamel Discoloration following Orthodontic Bracket Bonding

Introdouction: According to the importance of enamel discoloration and controversy regarding the effect of different orthodontic bonding materials on tooth discoloration, the aim of this study was to determine enamel discoloration following orthodontic brackets using different bonding materials. Materials and methods: This in-vitro study, 30 recently extracted human premolars with inta...

متن کامل

Prevention and Treatment of White Spot Lesions in Orthodontic Patients

Decalcification of enamel, appearing as white spot lesions (WSLs), around fixed orthodontic appliances is a major challenge during and after fixed orthodontic treatment by considering the fact that the goal of orthodontic treatment is to enhance facial and dental esthetic appearance. Banded or bonded teeth exhibit a significantly higher rate of WSLs compared to the controls with no braces as fi...

متن کامل

A review on preventive measures and treatment of white spot lesions in patients with fixed orthodontic appliances

Objective: One complication of fixed orthodontic treatment in patients with poor oral hygiene is development of demineralized enamel lesions compromising esthetics. This study aimed to review preventive measures and treatment of white spot lesions (WSLs) in patients with fixed orthodontic appliances. Review of Literature: In this review study, PubMed and Google Scholar databases were searched ...

متن کامل

Personified Orthodontic Treatment of Adults with Malocclusions and Deformations in Dentition Depending on the Degree of Caries Resistance of the Dental Enamel

Background: To increase the effectiveness of orthodontic treatment in children with various degrees of dental enamel caries resistance using a personified orthodontic treatment. Materials and Methods: The present study included 108 adults (6-16 years old) with the first class of occlusion who referred for the Department of Pediatric Dent...

متن کامل

بررسی تأثیر دو نوع ادهزیو و دو نوع وسیله دی باندینگ بر میزان ادهزیو باقیمانده بر روی مینای دندان

Background and Aim: At the end of fixed orthodontic treatment, enamel damages are affected by amount of adhesive remnants. Thus, determining the factors involves in the amount of adhesive remnants e.g. the types of resins and the methods used for debonding is of necessity. The aim of this study was to evaluate the effect of the composite resin type and debonding pliers on enamel surface by a ne...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 13  شماره 

صفحات  -

تاریخ انتشار 2014