Measurement of Kidney Volume with Multi-Detector Computed Tomography Scanning in Young Korean

نویسندگان

  • Ho Sik Shin
  • Byung Ha Chung
  • Sang Eun Lee
  • Woo Jin Kim
  • Hong Il Ha
  • Chul Woo Yang
چکیده

PURPOSE Kidney volume is regarded as the most precise indicator of kidney size. However, it is not widely used clinically, because its measurement is difficult due to the complex kidney shape. We attempted to evaluate the normal kidney volume in young Korean men by using multi-detector computed tomography (MDCT). MATERIALS AND METHODS We retrospectively reviewed MDCT data of young Korean men (113 patients). After data processing, we measured the volume and length of the kidneys. Body parameters (height, body weight, body-surface area, and total body water) and laboratory data were collected. Glomerular filtration rate (GFR) was calculated using Cockcroft-Gault (CG) equation. RESULTS The mean kidney volume was 205.29 +/- 36.81 cm(3); and mean kidney length was 10.80 +/- 0.69 cm. The former correlated significantly with height, body weight, body-surface area, and total body water (p < 0.05, correlation coefficient : gamma = 0.328, 0.649, 0.640, and 0.638, respectively). The latter also correlated significantly with all body indexes, however the correlation was weaker, except with height (p < 0.05, correlation coefficient : gamma = 0.457, 0.473, 0.505, and 0.503, respectively). Only kidney volume significantly predicted estimated GFR (adjusted R(2) = 0.431, F = 85.90 and p < 0.05). CONCLUSION The kidney volume measured with MDCT is correlated well with body parameters, and is useful to predict renal function.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Protective effects of pomegranate seed oil on ovariectomized rats as a model of postmenopausal osteoporosis: A multi-detector computed tomography evaluation

The pomegranate seed oil (PSO), containing 17-α-estradiol, is one of the newly found phytosterols with synergistic health effects on estrogen related physiological conditions. Herein, PSO was assessed for its potential improving effects on bone characteristics in a rat model of menopausal syndrome. Three month old non-pregnant female Wistar rats (n = 30) were either sham-operated (SHAM) or ovar...

متن کامل

Development of Computed Tomography Head and Body Phantom for Organ Dosimetry

Introduction: Quality assurance in Computed tomography (CT) centers in developing countries are largely hindered by the unavailability of CT phantoms. The development of a local CT phantom for the measurement of organ radiation absorbed dose is therefore requisite. Material and Methods: Local CT phantoms were designed to meet the standard criteria of 32 cm diameter for body, 16 cm diameter for...

متن کامل

Dose Reduction Methods in Chest Computed Tomography

Introduction: Computed tomography is one of the most powerful tools for investigating thorax disease, because it shows progression of lung disease much clearer than chest radiography. Technical advances in CT scanners have led to some abilities for CT scanners such as coverage of larger volume, lower noise and ability for acquiring image in one respiratory phase. However, this will be accompani...

متن کامل

Assessment of X-Ray Crosstalk in a Computed Tomography Scanner with Small Detector Elements Using Monte Carlo Method

Introduction: Crosstalk is a leakage of X-ray or light produced in a matrix of X-ray detectors or array of photodiodes in one element to other elements affecting on image contrast and spatial resolution. In this study, we assessed X-ray crosstalk in a computed tomography (CT) scanner with small detector elements to estimate the effect of various parameters such as X-ray tube voltage, detector e...

متن کامل

Measurement and Estimation of Renal Size by Computed Tomography in Korean Children

Adequate organ growth is an important aspect of growth evaluation in children. Renal size is an important indicator of adequate renal growth; computed tomography (CT) can closely estimate actual kidney size. However, insufficient data are available on normal renal size as measured by CT. This study aimed to evaluate the relationships of anthropometric indices with renal length and volume measur...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 50  شماره 

صفحات  -

تاریخ انتشار 2009