Safety of Landiolol Hydrochloride as a Premedication for Producing an Appropriate Heart Rate for Multidetector-Row Computed Tomography Coronary Angiography
نویسندگان
چکیده
Background We evaluated the safety of a bolus injection of landiolol hydrochloride, an ultrashort-acting β1-selective antagonist, as a premedication prior to multidetector-row computed tomography coronary angiography (CTA). Methods The subjects consisted of 176 patients (M/F = 64:112, 67 ± 11 years) who had heart rate (HR) at rest ≥ 70 beats/min (bpm) and underwent CTA. Systolic/diastolic blood pressure (SBP/DBP) and HR were measured before and after the administration of landiolol. Results SBP/DBP and HR upon entry to the CT room were 136 ± 17/80 ± 11 mm Hg and 83 ± 10 bpm, respectively. HR was significantly reduced at the time of CTA scan (62 ± 7 bpm). Next, we divided the patients into three groups according to HR upon entry to the CT room: 70 - 79 bpm (n = 76), 80 - 89 bpm (n = 60) and ≥ 90 bpm (n = 40). HR at the time of CTA scan was significantly lower than that upon entry to the CT room in all three groups: 70 - 79 bpm (74 ± 3 bpm upon entry to the CT room to 61 ± 6 bpm at the time of CAT scan), 80 - 89 bpm (84 ± 3 to 63 ± 7 bpm) and ≥ 90 bpm (98 ± 6 to 65 ± 7 bpm). Although SBP/DBP was significantly decreased after the CTA scan (123 ± 18/72 ± 12 mm Hg), landiolol had no severe adverse events throughout CTA. Conclusion In conclusion, a bolus injection of landiolol reduced HR by about 20 bpm without any severe adverse effects. Thus, a bolus injection of landiolol hydrochloride may be a suitable pretreatment for controlling HR in CTA.
منابع مشابه
A Multicenter, Open-Label Study of an Intravenous Short-Acting β1-Adrenergic Receptor Antagonist Landiolol Hydrochloride for Coronary Computed Tomography Angiography by 16-Slice Multi-Detector Computed Tomography in Japanese Patients with Suspected Ischemic Cardiac Disease
BACKGROUND During coronary computed tomography (CT) angiography (CCTA), β-blockers (β-adrenergic receptor antagonists) have commonly been used to lower heart rate and improve image quality. OBJECTIVES The aim of this study was to investigate the image quality-improving effect as well as the heart rate-lowering effect of landiolol hydrochloride (an intravenous short-acting β1-adrenergic recept...
متن کاملA Randomized, Double-Blind, Placebo-Controlled, Phase III Study of the Short-Acting β1-Adrenergic Receptor Blocker Landiolol Hydrochloride for Coronary Computed Tomography Angiography in Japanese Patients with Suspected Ischemic Cardiac Disease
OBJECTIVES AND BACKGROUND The objective of this study was to investigate the image quality-improving and heart rate-lowering effects of landiolol hydrochloride (a short-acting β1-adrenergic receptor blocker) on coronary computed tomography angiography (CCTA). During CCTA, β-adrenergic receptor blockers have been commonly used to lower heart rate and improve image quality. METHODS A total of 2...
متن کاملDose-Finding Study of Landiolol Hydrochloride: A Short-Acting β1-Blocker for Controlling Heart Rate During Coronary Computed-Tomography Angiography in Japan
INTRODUCTION Coronary computed-tomography angiography (CCTA) has high diagnostic performance, but it sometimes does not allow evaluation because of artifacts. Currently, the use of a β-blocker is recommended to prevent motion artifacts, but the β-blocker (metoprolol, propranolol, etc.) commonly used has a slow onset and long duration of action. Landiolol hydrochloride is an intravenous β1-block...
متن کامل256- and 320-row coronary CTA: is more better?
This editorial refers to ‘The diagnostic accuracy of 256row computed tomographic angiography compared with invasive coronary angiography in patients with suspected coronary artery disease’, by S.-P. Chao et al., on page 1916 and ‘Diagnostic accuracy of 320-row multidetector computed tomography coronary angiography in the noninvasive evaluation of significant coronary artery disease’, by F.R. de...
متن کاملDetection of coronary artery stenoses with thin-slice multi-detector row spiral computed tomography and multiplanar reconstruction.
BACKGROUND We analyzed the accuracy of multi-detector row spiral computed tomography (MDCT) using a 16-slice CT scanner with improved spatial and temporal resolution, as well as routine premedication with beta-blockers for detection of coronary stenoses. METHODS AND RESULTS Seventy-seven patients with suspected coronary disease were studied by MDCT (12x0.75-mm cross-sections, 420 ms rotation,...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 10 شماره
صفحات -