The influence of free hemoglobin and bilirubin on heparin monitoring by activated partial thromboplastin time and anti-Xa assay.

نویسندگان

  • Vadim Kostousov
  • Kim Nguyen
  • Shilpa G Hundalani
  • Jun Teruya
چکیده

CONTEXT Elevated free hemoglobin (Hb) and bilirubinemia complicate extracorporeal membrane oxygenation and could affect unfractionated heparin (UH) therapy monitoring by anti-Xa assay and activated partial thromboplastin time (aPTT). OBJECTIVES To compare in vitro response of anti-Xa and aPTT assays to UH in samples with artificial hyperbilirubinemia and hyperhemoglobinemia and to estimate if this interference is also observed in vivo in pediatric extracorporeal membrane oxygenation. DESIGN Measurement of aPTT and anti-Xa activity in plasma spiked with UH and increased concentration of free Hb and/or conjugated bilirubin. All samples with anti-Xa activity, antithrombin, free Hb, and bilirubin determination and infused dose of UH from inpatients on extracorporeal membrane oxygenation were extracted from the clinical patient database and analyzed. RESULTS Each increment of free Hb by 100 mg/dL significantly shortened aPTT, whereas an increment of bilirubin by 6 mg/dL caused significant prolongation of aPTT and stepwise increase of free Hb and/or bilirubin in plasma decreased anti-Xa activity by 0.03 to 0.05 IU/mL. Extracorporeal membrane oxygenation samples with free Hb 50 mg/dL or greater had significantly lower anti-Xa activity compared with normal ones: 0.33 (0.25-0.42) versus 0.4 (0.31-0.48) IU/mL (P = .01), despite the identical UH infusion and similar antithrombin activity. Moderate increase of free Hb by 59 mg/dL was associated with absolute decrease of anti-Xa activity by 0.07 IU/mL. CONCLUSIONS Activated partial thromboplastin time and anti-Xa assay are affected by elevated level of free Hb and/or bilirubin in the presence of UH, and lower anti-Xa activity is noted in extracorporeal membrane oxygenation patients with elevated free Hb. Severe hemolysis and/or hyperbilirubinemia could compromise UH monitoring based on these assays.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Concordance between Activated Partial Thromboplastin Time and Antifactor Xa Assay for Monitoring Unfractionated Heparin in Hospitalized Hyperbilirubinemic Patients.

BACKGROUND Activated partial thromboplastin time (aPTT) and antifactor Xa (anti-Xa) monitoring methods for unfractionated heparin (UFH) often disagree. The extent of discordance for those with elevated bilirubin remains unclear. Our objective was to evaluate concordance between activated aPTT and anti-Xa methods for hyperbilirubinemic patients on UFH. METHODS This was a retrospective cohort s...

متن کامل

Automated amidolytic method for determining heparin, a heparinoid, and a low-Mr heparin fragment, based on their anti-Xa activity.

Using the chromogenic substrate S-2222, we have optimized and automated an amidolytic assay for heparin. The assay is based on the detection of anti-Xa activity generated by heparin in plasma. The method is reproducible (intra- and interassay CVs of 2.4 and 3.3%, respectively) and reliable in antithrombin III-deficient plasma. Results of this assay, obtained for plasma samples from patients and...

متن کامل

Lack of correlation between heparin dose and standard clinical monitoring tests in treatment with unfractionated heparin in critically ill children.

UNLABELLED The activated partial thromboplastin time (aPTT) and anti-Xa activity are used for monitoring unfractionated heparin (UFH) therapy in children and may not be optimal. OBJECTIVE Determine correlations of aPTT, anti-Xa and UFH dose in children. Single centre prospective cohort study in children receiving UFH. The aPTT and anti-Xa results from routine coagulation monitoring were colle...

متن کامل

Activated partial thromboplastin time versus antifactor Xa heparin assay in monitoring unfractionated heparin by continuous intravenous infusion.

BACKGROUND Unfractionated heparin (UFH) has been used clinically for 5 decades. Despite being a cornerstone of anticoagulation, UFH is limited by its unpredictable pharmacokinetic profile, which makes close laboratory monitoring necessary. The most common methods for monitoring UFH are the activated partial thromboplastin time (aPTT) and antifactor Xa heparin assay (anti-Xa HA), but both presen...

متن کامل

Establishing the heparin therapeutic range using aPTT and anti-Xa measurements for monitoring unfractionated heparin therapy

BACKGROUND Unfractionated heparin (UFH) has unstable pharmacokinetics and requires close monitoring. The activated partial thromboplastin time (aPTT) test has been used to monitor UFH therapy for decades in Korea, but its results can be affected by numerous variables. We established an aPTT heparin therapeutic range (HTR) corresponding to therapeutic anti-Xa levels for continuous intravenous UF...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Archives of pathology & laboratory medicine

دوره 138 11  شماره 

صفحات  -

تاریخ انتشار 2014