Which orthodontic archwire sequence? A randomized clinical trial.

نویسندگان

  • Na Mandall
  • C Lowe
  • Hv Worthington
  • J Sandler
  • S Derwent
  • M Abdi-Oskouei
  • S Ward
چکیده

The aim of this study was to compare three orthodontic archwire sequences. One hundred and fifty-four 10- to 17-year-old patients were treated in three centres and randomly allocated to one of three groups: A = 0.016-inch nickel titanium (NiTi), 0.018 x 0.025-inch NiTi, and 0.019 x 0.025-inch stainless steel (SS); B = 0.016-inch NiTi, 0.016-inch SS, 0.020-inch SS, and 0.019 x 0.025-inch SS; and C = 0.016 x 0.022-inch copper (Cu) NiTi, 0.019 x 0.025-inch CuNiTi, and 0.019 x 0.025-inch SS. At each archwire change and for each arch, the patients completed discomfort scores on a seven-point Likert scale at 4 hours, 24 hours, 3 days, and 1 week. Time in days and the number of visits taken to reach a 0.019 x 0.025-inch SS working archwires were calculated. A periapical radiograph of the upper left central incisor was taken at the start of the treatment and after placement of the 0.019 x 0.025-inch SS wire so root resorption could be assessed. There were no statistically significant differences between archwire sequences A, B, or C for patient discomfort (P > 0.05) or root resorption (P = 0.58). The number of visits required to reach the working archwire was greater for sequence B than for A (P = 0.012) but this could not be explained by the increased number of archwires used in sequence B.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pain control in orthodontics using vibration

Pain is a common patient complaint during the orthodontic movement of teeth, especially immediately following archwire placement. Vibration has been used to accelerate the orthodontic movement of teeth and some observations by clinicians have indicated that vibration appeared to reduce the pain of orthodontic treatment. The purpose of this parallel group, randomized clinical trial was to invest...

متن کامل

Self-ligating fully customized lingual appliance and chair-time reduction: a typodont study followed by a randomized clinical trial.

In this study, we tested the hypothesis that self-ligation can reduce the chair time necessary for inserting and removing the archwire in a fully customized, multi-bracket, orthodontic, lingual appliance. A permuted-block, randomized trial design was employed to treat seven patients, each with Incognito(®) lingual appliances and Harmony(®) self-ligating lingual appliances. Three operators (a th...

متن کامل

The effect of chewing gum on the impact, pain and breakages associated with fixed orthodontic appliances: a randomized clinical trial.

OBJECTIVES To determine whether the use of chewing gum reduced the impact and pain of fixed orthodontic appliances. SETTING AND SAMPLE POPULATION The Orthodontic Department of the Charles Clifford Dental Hospital, Sheffield, UK. Fifty-seven patients aged 18 years or younger and who were about to start fixed orthodontic appliance treatment. SUBJECTS AND METHODS A randomized clinical trial wi...

متن کامل

Galvanic Corrosion among Different Combination of Orthodontic Archwires and Stainless Steel Brackets

Introduction: The aim of this study was to assess the galvanic behavior of different bracket and archwire combinations that are commonly used in orthodontic treatments. Methods: Three types of orthodontic archwires with a diameter of 0.016×0.022 inch and 80 standard edgewise maxillary central incisor brackets were selected. Three groups consisted of different wire-bracket couples and one group ...

متن کامل

The dynforce archwire.

This article is a presentation of a clinical methodology aimed at minimizing binding in fixed orthodontic appliances. The dynforce archwire is explained. The dynforce archwire has a full size anterior segment (e.g. .021×.025) and undersized posterior segments with rectangular cross-section (e.g. .018×.025 or .018×.022), and is used in the orthodontic phase of space closure with or without TAD m...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European journal of orthodontics

دوره 28 6  شماره 

صفحات  -

تاریخ انتشار 2006