[Evaluation of the accuracy of a compensating filter based on compact NC-Mill for radiation therapy].

نویسندگان

  • Hiroshi Oguchi
  • Masanori Miyazawa
  • Masaomi Takizawa
چکیده

The present report describes the fabrication technique and dosimetry aspects of a desktop numerically controlled milling machine (NC-Mill) based a compensator system that uses lead clay (Shield cray, Reactor Experiments, Inc., U.S.A.). Effective path lengths of patients were determined for CT image sets using the ray-tracing technique and converted to compensator thickness with the equivalent TMR method. Rigid urethane foam was processed with the NC-Mill to produce a mold for filters, and the lead clay was adopted as the compensating material. The dose distribution was measured on the compensating plane of an anthropomorphic phantom and a stair-step PMMA phantom. It was found that the radiation field with inhomogeneous dose was as high as 30%+/-3% with the compensating filters. In addition, when the absorbed dose at the central axis of 52 compensating filters that were used clinically was measured, 75.0% showed an error of less than +/-3%, and 3.8% showed the maximum dose error: >+/-5%. Overall, the present system was capable of producing dose uniformity to within +/-5% for a stair-step phantom, an anthropomorphic phantom, and clinical situations.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Accuracy Evaluation of Isogray TPS Dose Calculations in Symmetric and Asymmetric Fields of the Elekta Compact Linear Accelerator

Introduction: Radiation therapy is one of the most important methods of cancer treatment. Radiation therapy uses symmetric and asymmetric fields in which the radiation dose distribution is different. To calculate the dose distribution, computer treatment planning systems are used which must have acceptable calculations accuracy. The aim of this study was to investigate the accuracy of the dose ...

متن کامل

Optimised BNCT facility based on a compact D-D neutron generator

Background: Boron Neutron Capture Therapy (BNCT) is a very promising treatment for patients suffering gliobastoma multiforme, an aggressive type of brain cancer, where conventional radiation therapies fail. Thermal neutrons are suitable for the direct treatment of cancers which are located at near-tissue-surface deep-seated tumors need harder, epithermal neutron energy spectra. Materials and Me...

متن کامل

Telecobalt Machine Beam Intensity Modulation with Aluminium Compensating Filter Using Missing Tissue Approach

Introduction: The present study aimed to generate intensity-modulated beams with Aluminium compensating filters for a conventional telecobalt machine based on the outputs of a treatment planning system (TPS) performing forward planning and cannot simulate directly the compensating filter. Materials and Methods: In order to achieve the beam intensity modulation during treatment planning with th...

متن کامل

Active Filter Control Method Based on Direct Power Control for Compensating Reactive Powers due to Unbalanced Voltages and Nonlinear Loads

Active filters have proven to be more effective than passive techniques to improve power quality and to solve harmonic and power factor problems due to nonlinear loads. This paper proposes a control scheme based on the instantaneous active and reactive power. The inverter of this active filter is a three-phase, two-level converter. Space vector technique is used as modulators and pattern genera...

متن کامل

Usability assessment of cone beam computed tomography with a full-fan mode bowtie filter compared to that with a half-fan mode bowtie filter

Background: In intensity modulated radiation therapy, cone beam computed tomography (CT) has been used to evaluate patients prior to treatment. This study conducted a comparative evaluation of the image reconstruction ability of the clinically used half-fan bowtie filter and the full-fan bowtie filter. Materals and Methods: A CT simulation marker was inserted inside a human phantom, and the pel...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Nihon Hoshasen Gijutsu Gakkai zasshi

دوره 63 8  شماره 

صفحات  -

تاریخ انتشار 2007