An evaluation of a bioelectrical impedance analyser for the estimation of body fat content.
نویسنده
چکیده
Measurement of body composition is an important part of any assessment of health or fitness. Hydrostatic weighing is generally accepted as the most reliable method for the measurement of body fat content, but is inconvenient. Electrical impedance analysers have recently been proposed as an alternative to the measurement of skinfold thickness. Both these latter methods are convenient, but give values based on estimates obtained from population studies. This study compared values of body fat content obtained by hydrostatic weighing, skinfold thickness measurement and electrical impedance on 50 (28 women, 22 men) healthy volunteers. Mean(s.e.m.) values obtained by the three methods were: hydrostatic weighing, 20.5(1.2)%; skinfold thickness, 21.8(1.0)%; impedance, 20.8(0.9)%. The results indicate that the correlation between the skinfold method and hydrostatic weighing (0.931) is somewhat higher than that between the impedance method and hydrostatic weighing (0.830). This is, perhaps, not surprising given the fact that the impedance method is based on an estimate of total body water which is then used to calculate body fat content. The skinfold method gives an estimate of body density, and the assumptions involved in the conversion from body density to body fat content are the same for both methods.
منابع مشابه
Bioelectrical Impedance versus Body Mass Index for Predicting Body Composition Parameters in Sedentary Job Women
Objective: Nowadays the value of bioelectrical impedance analysis (BIA) in the estimation of body adiposity both on a clinical basis in the individual and epidemiologically in large populations is of great interest. The current study determine accuracy of BIA compared with body mass index (BMI) measurement for estimating body composition in a group of normal weight employee women with a sedenta...
متن کاملComparison of Total Fat, Percentage of Fat, Trunk Fat, Soft Lean and Mass Waist-Hip Ratio between Diabetic type II and Matched Non-Diabetic Iranians using Bioelectrical Impedance Analysis
Introduction: Research shows a relationship between diabetes (type II) and obesity. Bioelectrical Impedance Analysis (BIA) is a relatively new and approved method for the measurement of body composition. The aim of this study was to compare diabetic and non-diabetic adults on the basis of waist-hip ratio, total fat, percentage of fat, trunk fat, and soft lean mass. Methods: In this cross-sec...
متن کاملValidation of ‘InBody’ Bioelectrical Impedance by Whole Body MRI
MRI has been shown to be an excellent technique for measuring body fat content, with it's ability to separately quantify specific fat compartments being a real advantage over other techniques. However, it is not suitable for large population studies. Bioelectrical impedance is widely used as a method for assessing body composition, however previous studies have found there is good correlation b...
متن کاملEvaluation of the novel Tanita body-fat analyser to measure body composition by comparison with a four-compartment model.
The Tanita body-fat analyser is a novel device to estimate body fat, based on the principles of bioelectrical impedance. It differs from other impedance systems which use surface electrodes in that the subjects stand bare-footed on a metal sole-plate which incorporates the electrodes, hence impedance is measured through the legs and lower trunk. In 104 men and 101 women (16-78 years and BMI 16-...
متن کامل[Formulation of an equation to predict fat mass using bioelectrical impedance in adults in a wide range of ages and body mass index].
BACKGROUND Bioelectrical impedance (BIA) has a good correlation and agreement with reference techniques, such as dual energy X-ray absorptiometry (DEXA), to assess body composition. AIM To develop and assess the concordance of an equation to predict body fat mass derived from anthropometric data, gender, age and resistance obtained from bioelectrical impedance in adults, using DEXA as the ref...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- British journal of sports medicine
دوره 27 1 شماره
صفحات -
تاریخ انتشار 1993