How accurate are lactate dehydrogenase isoenzyme estimations by the thin-layer agarose fluorescent technique?
نویسندگان
چکیده
We offer an assessment of the accuracy of the thin-layer agarose fluorescent technique of Elevitch et al. [Am. J. Clin. Pathol. 46, 692 (1966)]. We used semi-purified human lactate dehydrogenase isoenzymes 1 and 5. Both the lactate lead to pyruvate and pyruvate lead to lactate assays [Clin. Chem. 20, 1462 (1974)] appear to give, within the errors of the techniques used, a substantially unbiased estimate of both LD-1 and LD-5, although this must remain a provisional conclusion until a definitive method of assay for the total and isoenzymic LD activities is created. Introducing a buffer into the substrate mixture (lactate lead to pyruvate assay) had no effect on these findings except at extremes of pH, when marked inaccuracies occurred.
منابع مشابه
Glucose Estimated with a Beckman Glucose Analyzer 2 In Spots of Capillary Blood on Filter
1. Papadopoulos, N. M., and Hufnagel, C. A., Evaluation of lactate dehydrogenase isoenzyme patterns in serum of patients undergoing cardiac surgery. J. Thorac. Cardiovasc. Surg. 76, 173-177 (1978). 2. McKenzie, D., Clarke, P. I., and Henderson, A. R., How accurate are lactate dehydrogenase isoenzyme estimations by the thin-layer agarose fluorescent technique? Clin. Chem. 22, 1995-1998 (1976). 3...
متن کاملGlucose estimated with a Beckman Glucose Analyzer 2 in spots of capillary blood on filter paper.
1. Papadopoulos, N. M., and Hufnagel, C. A., Evaluation of lactate dehydrogenase isoenzyme patterns in serum of patients undergoing cardiac surgery. J. Thorac. Cardiovasc. Surg. 76, 173-177 (1978). 2. McKenzie, D., Clarke, P. I., and Henderson, A. R., How accurate are lactate dehydrogenase isoenzyme estimations by the thin-layer agarose fluorescent technique? Clin. Chem. 22, 1995-1998 (1976). 3...
متن کاملInfluence of hemolysis on the serum lactate dehydrogenase-1/lactate dehydrogenase-2 ratio as determined by an accurate thin-layer agarose electrophoresis procedure.
The accuracy of our lactate dehydrogenase (EC 1.1.1.27) isoenzyme procedure, based on electrophoresis in thin-layer agarose, has previously been assessed (Clin. Chem. 22: 1995, 1976). We now show that the method is similarly accurate and precise for the specific measurements of lactate dehydrogenase isoenzyme-1 and -2. We have also determined the lactate dehydrogenase isoenzyme pattern in perip...
متن کاملThin-layer agarose electrophoresis of lactate dehydrogenase isoenzymes in serum: a note on the method of reporting and on the lactate dehydrogenase isoenzyme-1/isoenzyme-2 ratio in acute myocardial infarction.
We assessed the clinical efficacy of a thin-layer agarose electrophoresis assay for lactate dehydrogenase isoenzyme estimation in the diagnosis of acute myocardial infarction. From a population of 228 patients admitted to the Coronary Care Unit with suspected acute myocardial infarction, all 101 positive cases (confirmed by clinical presentation and electrocardiographic changes) were correctly ...
متن کاملPurification of lactate dehydrogenase isoenzyme-5 from human liver.
We present a method for preparing human liver lactate dehydrogenase (L-lactate:NAD+ oxidoreductase; EC 1.1.1.27) isoenzyme-5 by sequential ion-exchange chromatography, general-ligand (AMP analog) affinity chromatography, and preparative isoelectric focusing. The yield ws 40%, with a 493-fold purification. The final specific activity was 458 kU per gram of protein. The preparation contained less...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 22 12 شماره
صفحات -
تاریخ انتشار 1976