Reproducibility of fetal limbs volume by three- dimensional ultrasonography utilizing the XI VOCAL method*

نویسندگان

  • Rafael Oliveira Cavalcante
  • Edward Araujo Júnior
  • Liliam Cristine Rolo
  • Antonio Fernandes Moron
چکیده

OBJECTIVE: To assess the reproducibility of fetal thigh and upper arm volumes measurement by threedimensional ultrasonography utilizing the eXtended Imaging Virtual Organ Computer-aided AnaLysis (XI VOCAL) method. MATERIALS AND METHODS: This reproducibility study enrolled 43 pregnant women with healthy singleton pregnancies between 20 and 37 gestational weeks. The XI VOCAL 10 planes was the method utilized for volumetric measurement of the fetal limbs. The calculation of the interobserver reproducibility was based on blind volumetric measurements of fetal thighs and upper-arms performed by two observers in 43 fetuses. Intraclass correlation coefficient (ICC), Bland-Altman plots and paired Student’s t-test (p) were utilized in the statistical analysis. RESULTS: A high interobserver reproducibility was observed. For the upper arm volume ICC was 0.996 (confidence interval [CI] 95%: 0.992; 0.998) and mean difference = 0.13 ± 1.29% (95% limits of agreement: –2.54; +2.54%). For the thigh volume, ICC was 0.997 (CI 95%: 0.995; 0.999) and mean difference = 0.24 ± 7.60% (95% limits of agreement: –7.6; +7.6%). CONCLUSION: Fetal thigh and upper arm volumes measured by three-dimensional ultrasonography with the XI VOCAL method presented a high interobserver reproducibility.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Reproducibility of fetal heart volume by 3D-sonography using the XI VOCAL method

BACKGROUND To assess the reliability of fetal heart volume measurement by three-dimensional sonography (3DUS) using the eXtended Imaging Virtual Organ Computer-aided AnaLysis (XI VOCAL) method. METHODS This reliability study enrolled 30 pregnant women with singleton healthy pregnancies between 19 and 34 weeks of gestation. All volume acquirements were performed with a convex volumetric transd...

متن کامل

Estimation of placental volume by three-dimensional ultrasonography with the XI VOCAL method in the first gestational trimester*

OBJECTIVE: To determine reference values for placental volume at 7 to 10 + 6 weeks of gestation by means of three-dimensional ultrasonography with the XI VOCAL (eXtended Imaging Virtual Organ Computer-aided Analysis) method. MATERIALS AND METHODS: A cross-sectional study was developed with 70 pregnant women at 7 to 10 + 6 weeks of gestation. The XI VOCAL method with ten sequential adjacent plan...

متن کامل

Assessment of renal volume by three-dimensional ultrasonography in pregnant bitches: an experimental study using virtual organ computer-aided analysis

BACKGROUND To assess and to compare the renal volume evolution in bitches during pregnancy by two-dimensional (2D) ultrasonography using the ellipsoid technique (volume = length x width x depth x 0.523) and three-dimensional (3D) ultrasonography using the Virtual Organ Computer-aided AnaLysis (VOCAL) method. A longitudinal prospective study was performed with 17 normal Golden Retrievers bitches...

متن کامل

Possibility and Reproducibility of Renal Assessing and Size Measurement by Three- Dimensional vs Two- Dimensional Ultrasounographv in Dogs

Objective- To determine the possibility and reproducibility of three-dimensional ultrasonography (3DUS)and comparison of the achieved measurements to normal two-dimensional ultrasonography (2DCS)Design- Descriptive studyAnimals- 10 young mixed normal dogs, age 1.5-2.5 year, weighing 9.7-12 kg Procedure- Renal width, length, and depth measured in coron al and transverse sections. The measurement...

متن کامل

Assessing the accuracy and reliability of ultrasonographic three-dimensional parathyroid volume measurement in a patient with secondary hyperparathyroidism: a comparison with the two-dimensional conventional method

PURPOSE The purpose of this study was to investigate the accuracy and reliability of the semi-automated ultrasonographic volume measurement tool, virtual organ computer-aided analysis (VOCAL), for measuring the volume of parathyroid glands. METHODS Volume measurements for 40 parathyroid glands were performed in patients with secondary hyperparathyroidism caused by chronic renal failure. The v...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010