ESR investigation of sucrose radicals produced by 0.25−4.5 Gy doses of X-ray irradiation
نویسندگان
چکیده
We investigated stable radicals produced by 0.25-4.5 Gy doses of X-ray irradiation of sucrose. Electron spin resonance (ESR) is able to observe the signal from sucrose irradiated at 0.25 Gy. The ESR signal intensity of the radicals is related to the accumulated dose, and it increases linearly with increasing absorbed dose. In addition, we examined the effect of dose rate (0.50-1.5 Gy/min) on the signal intensity of the irradiated sucrose. The stable radical production did not exhibit dose rate dependence. In addition, the peak corresponding to the irradiated glucose was observed to increase more with increasing absorbed dose than the peak corresponding to irradiated fructose. Therefore, the present ESR results regarding the 0.25-4.5 Gy irradiation of sucrose provide new insights into a possible sucrose ESR dosimeter.
منابع مشابه
Investigation of the production of free radicals in ultraviolet irradiation using SnO2:Eu nanoparticles
In studying the ultraviolet (UV) radiation, one of the important factors is the possibility of generating a variety of free radicals inside the body by these radiations. In this paper, a method of estimating the amount of hydroxyl radicals produced by ultraviolet rays was investigated using nanoparticles of tin oxide doped with uropium. In this method, the change in absorption intensity of meth...
متن کاملHeavy-ion-induced sucrose radicals investigated using EPR and UV spectroscopy
The potential use of a sucrose dosimeter for estimating both linear energy transfer (LET) and the absorbed dose of heavy ion and X-ray radiation was investigated. The stable free radicals were produced when sucrose was irradiated with heavy ions, such as helium, carbon, silicon and neon ions, and when the X-ray radiation was similar to the obtained electron paramagnetic resonance (EPR) spectra,...
متن کاملEffects of High Doses of X-Ray on Hematological Parameters and Morphology of Red Blood Cells in Human Blood
Introduction: The aim of the current study was to investigate the effects of X-ray radiation on some hematological parameters, morphology of red blood cells (RBC) and erythrocyte sedimentation rate (ESR) analysis of human blood using computed tomography (CT) scanner. Material and Methods: For the purpose of the study, 5 ml of wholeblood was drawn from vein puncture of 28 healthy people and div...
متن کاملBiological Dose Assessment by Chemical Induction of Premature Chromosome Condensation
Dose assessment of radiation victims is a key element in medical management of radiation accidents. At high radiation doses (> 6 Gy), dicentric assay lose its efficiency and premature chromosome condensation (PCC) assay was proposed to overcome the restrictions of dicentric assay. It was shown that PCC ring is more suitable and simpler than dicentric for biodosimetry in high radiation doses. In...
متن کاملVerification of the PAGAT polymer gel dosimeter by photon beams using magnetic resonance imaging
Background: In this work investigation of the normoxic PAGAT polymer gel dosimeter such as sensitivity, the R2-dose response with post time and the percentage depth dose (PDD) of PAGAT polymer gel dosimeter have been undertaken. Materials and Methods: Using MRI, the formulation to give the maximum change in the transverse relaxation rate R2 was determined to be 4.5% N,N'-methylenbis- ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 55 شماره
صفحات -
تاریخ انتشار 2014