Safety and efficiency of ventricular pacing prevention with an AAI-DDD changeover mode in patients with sinus node disease or atrioventricular block: impact on battery longevity—a sub-study of the ANSWER trial
نویسندگان
چکیده
AIMS This ANSWER (EvaluAtioN of the SafeR mode in patients With a dual chambER pacemaker indication) sub-study assesses safety and effectiveness of SafeR™ and the impact of ventricular pacing (VP) prevention on anticipated device longevity and replacement rate. METHODS AND RESULTS Patients implanted for atrioventricular block (AVB, n = 310) or sinus node dysfunction (SND, n = 336) were randomly assigned to SafeR (n = 314) or DDD (n = 318) and followed for 36 months. Safety, median VP, estimated device longevity (mean difference, 95% confidence interval [CI]), and anticipated replacement rates were analysed by pacing mode and implant indication. No difference in mortality, syncope, or mode intolerance was observed between randomization groups regardless of the indication. Ventricular pacing on SafeR vs. DDD was 11.5 vs. 93.6% in the overall population (P < 0.001), 89.2 vs. 83.8% in permanent AVB (P = 0.944), 53.5 vs. 98.2% in intermittent AVB (P < 0.001), and 2.2 vs. 84.7% in SND (P < 0.001). Anticipated median device longevity increased on SafeR by 14 [Q1 10; Q3 17] months [10; 17] (P < 0.001) in the overall population, 9 months [-5; 22] (P = 0.193) in permanent AVB, 14 months [8; 19] (P < 0.001) in intermittent AVB, and 14 months [9; 19] (P < 0.001) in SND. In intermittent AVB and SND, prolonged estimated battery longevity translated into the prevention of one anticipated replacement in at least 23% of patients. CONCLUSION SafeR was effective in reducing VP in intermittent AVB and in SND. No effect was observed in permanent AVB. No safety issue was observed. Ventricular pacing reduction by SafeR translated into relevant estimated prolongation of device longevity and anticipated reduction of required replacements.
منابع مشابه
Long-term clinical effects of ventricular pacing reduction with a changeover mode to minimize ventricular pacing in a general pacemaker population
AIM Right ventricular pacing (VP) has been hypothesized to increase the risk in heart failure (HF) and atrial fibrillation (AF). The ANSWER study evaluated, whether an AAI-DDD changeover mode to minimize VP (SafeR) improves outcome compared with DDD in a general dual-chamber pacemaker population. METHODS AND RESULTS ANSWER was a randomized controlled multicentre trial assessing SafeR vs. stan...
متن کامل[Clinical safety and efficacy of single-chamber atrial pacing in sick sinus syndrome: long-term follow-up].
INTRODUCTION AND OBJECTIVES Although atrial pacing is a more physiological mode of stimulation in sinus node dysfunction, the pacing modes most often are used DDD and VVI. The aim of our study was to demonstrate that AAI/AAIR pacing is effective and safe by analyzing the complications and mortality of this pacing mode in a long-term follow-up study. PATIENTS AND METHOD Between 1982 and 2000 d...
متن کاملLong-Term Outcome of Single-Chamber Atrial Pacing Compared with Dual-Chamber Pacing in Patients with Sinus-Node Dysfunction and Intact Atrioventricular Node Conduction
PURPOSE The optimal pacing mode with either single chamber atrial pacemaker (AAI or AAIR) or dual chamber pacemaker (DDD or DDDR) is still not clear in sinus-node dysfunction (SND) and intact atrioventricular (AV) conduction. MATERIALS AND METHODS Patients who were implanted with permanent pacemaker using AAI(R) (n = 73) or DDD(R) (n = 113) were compared. RESULTS The baseline characteristic...
متن کاملPhysiological pacing: a moving target?
During the 1990s and the early years of the 2000s, there was considerable debate on the advantages of ‘physiological’ pacing, which at that time denoted dual-chamber vs. single-chamber pacing. A series of landmark studies, including the MOST, PASE, CTOPP, and UKPACE trials, randomized patients with various indications for pacing into DDD vs. VVI pacing modes. Despite high hopes and great belief...
متن کاملAtrial vs. dual-chamber cardiac pacing in sinus node disease: a register-based cohort study.
AIMS In patients with sinus node disease, dual-chamber pacing (DDD) possibly results in adverse effects on the ventricular function. We have compared the incidence of cardiovascular morbidity and mortality in patients with sinus node disease and with atrioventricular (AV) synchronous pacemakers, DDD vs. atrial pacing (AAI). METHODS AND RESULTS A nation-wide population-based cohort of 8777 pat...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 18 شماره
صفحات -