Fast phase-modulated B1+ mapping in the low flip-angle regime

نویسندگان

  • A. L. van Lier
  • J. M. Hoogduin
  • D. J. Klomp
  • J. J. Lagendijk
  • C. A. van den Berg
چکیده

Introduction and purpose: In high-field MRI phased transmit arrays are used to mitigate RF issues, e.g. optimizing the inhomogeneous B1 field using spatially tailored RF pulses played out by such an array. In order to design the RF pulses that produce the desired excitation field, the B1 field per coil must be mapped. Ideally, these B1 mapping techniques are fast and have a low SAR deposition. However, most of the contemporary B1 mapping techniques require large flip angles [1,2] and are therefore accompanied by relatively high SAR values. As a consequence, lengthy acquisition times are needed to stay within SAR limits. In this abstract we describe a fast method to measure the B1 field per coil in the low flipangle regime, using phase modulated 3D low flip angle (PMLF) GRE images.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Very Fast Multi Channel B1 Calibration at High Field in the Small Flip Angle Regime

Transmit SENSE. For this purpose, an ROI was drawn in the occipital lobe (white ROI Fig3) and two B1 Phase Shim solutions were calculated and applied in order to obtain an homogeneous B1 magnitude within this ROI: one based on the estimated B1 maps, another one based on the measured B1 maps. As can be seen in Fig3 (in degrees), both B1 Shim sets produced tremendous improvement in B1 efficiency ...

متن کامل

B 1 Correction using Dual Tau Look - Locker ( D τ LL )

Introduction: Transmit B1 inhomogeneity has become an increasingly obvious problem in high field human MRI. As higher field main magnets are used, wavelength effects distort the RF field, leading to image intensity gradients and incorrect values in quantitative maps, in particular in fast T1 and T2 mapping methods such as DESPOT1 and DESPOT2 [1], which require accurate knowledge of the flip ang...

متن کامل

Fast and Robust B1 Mapping at 7T by the Bloch-Siegert Method

Introduction: B1 mapping has a variety of applications including the design of RF pulses in parallel transmit systems, and flip angle calibration for T1 mapping. Many existing B1 mapping methods suffer from T1 dependence, long scan time or inability to handle the large B1 inhomogeneity that occurs even across the human brain at 7T. The Bloch-Siegert B1 mapping method has been recently introduce...

متن کامل

Comparison between RF spoiling schemes in the Actual Flip-angle Imaging (AFI) sequence for fast B1 mapping

Fig. 3. Simulated dependences of the measured flip angle on φ0 in the weak (a) and strong (b-d) spoiling regimes for n=5 (a,b: parameters from Fig. 2); n=4 (c: TR1/TR2=20/80 ms, AG1/AG2= 204/816 mT·ms/m); and n=3 (d: TR1/TR2=20/60 ms, AG1/AG2=255/765 mT·ms/m). Black and gray lines correspond to the standard (1,2) and modified (3) RF spoiling schemes. For plots (b-d), the constant spoiler area i...

متن کامل

SNR Analysis of Variable Refocusing Flip Angle FSE

R. F. Busse Applied Science Lab West, GE Medical Systems, Menlo Park, CA, United States Introduction For fast spin echo sequences, power can be greatly reduced while suffering only modest reduction in signal by using low flip angle refocusing pulses, provided the flip angles of the first few pulses are modulated so as to maintain pseudo-steady-state (pss) conditions in the spin system (1). Rece...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009