Retrieving impulse response function amplitudes from the ambient seismic field

نویسندگان

  • Loı̈c Viens
  • Marine Denolle
  • Hiroe Miyake
  • Shin’ichi Sakai
  • Shigeki Nakagawa
چکیده

S U M M A R Y Seismic interferometry is now widely used to retrieve the impulse response function of the Earth between two distant seismometers. The phase information has been the focus of most passive imaging studies, as conventional seismic tomography uses traveltime measurements. The amplitude information, however, is harder to interpret because it strongly depends on the distribution of ambient seismic field sources and on the multitude of processing methods. Our study focuses on the latter by comparing the amplitudes of the impulse response functions calculated between seismic stations in the Kanto sedimentary basin, Japan, using several processing techniques. This region provides a unique natural laboratory to test the reliability of the amplitudes with complex wave propagation through the basin, and dense observations from the Metropolitan Seismic Observation network. We compute the impulse response functions using the cross correlation, coherency and deconvolution techniques of the raw ambient seismic field and the cross correlation of 1-bit normalized data. To validate the amplitudes of the impulse response functions, we use a shallow Mw 5.8 earthquake that occurred on the eastern edge of Kanto Basin and close to a station that is used as the virtual source. Both S and surface waves are retrieved in the causal part of the impulse response functions computed with all the different techniques. However, the amplitudes obtained from the deconvolution method agree better with those of the earthquake. Despite the expected wave attenuation due to the soft sediments of the Kanto Basin, seismic amplification caused by the basin geometry dominates the amplitudes of S and surface waves and is captured by the ambient seismic field. To test whether or not the anticausal part of the impulse response functions from deconvolution also contains reliable amplitude information, we use another virtual source located on the western edge of the basin. We show that the surface wave amplitudes of the anticausal part agree well with those of a shallow Mw 4.7 event that occurred close to the virtual source. This study demonstrates that the deconvolution technique seems to be the best strategy to retrieve reliable relative amplitudes from the ambient seismic field in the Kanto Basin.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Preface to the special issue on ambient noise seismology∗

Not too long ago, seismic imaging of the Earth’s interior relied almost exclusively on the illumination from energetic sources, such as earthquakes or artificial sources. However, recent theoretical and laboratory studies have shown that the impulse response (Green’s function) of a structure between two receivers can be obtained from the cross-correlation of “random” noise wavefields recorded a...

متن کامل

Ground motion prediction of realistic earthquake sources using the ambient seismic field

[1] Predicting accurate ground motion is critical for earthquake hazard analysis, particularly in situations where sedimentary basins trap and amplify seismic waves. We exploit the information carried by the ambient seismic field to extract surface-wave Green’s functions between seismic stations and to predict long-period ground motion from earthquakes. To do so, we modify the surface impulse r...

متن کامل

Bayesian characterization of buildings using seismic interferometry on ambient vibrations

Continuous monitoring of engineering structures provides a crucial alternative to assess its health condition as well as evaluate its safety throughout the whole service life. To link the field measurements to the characteristics of a building, one option is to characterize and update a model, against the measured data, so that it can best describe the behavior and performance of the structure....

متن کامل

Short Note Impulse Response of Civil Structures from Ambient Noise Analysis

Increased monitoring of civil structures for response to earthquake motions is fundamental to reducing seismic risk. Seismic monitoring is difficult because typically only a few useful, intermediate to large earthquakes occur per decade near instrumented structures. Here, we demonstrate that the impulse response function (IRF) of a multistory building can be generated from ambient noise. Estima...

متن کامل

Time-lapse monitoring of internal erosion in earthen dams and levees using ambient seismic noise

Earthen dams and levees are prone to progressive failure through internal erosion of their structure. Internal erosion is often invisible to current methods of inspection until it manifests itself at the exterior surface. This study focuses on the novel use of passive seismic interferometry to monitor temporal changes in earthen embankments caused by internal erosion. This technique uses the am...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2017