Intra-aneurysmal thrombosis as a possible cause of delayed aneurysm rupture after flow-diversion treatment.

نویسندگان

  • Z Kulcsár
  • E Houdart
  • A Bonafé
  • G Parker
  • J Millar
  • A J P Goddard
  • S Renowden
  • G Gál
  • B Turowski
  • K Mitchell
  • F Gray
  • M Rodriguez
  • R van den Berg
  • A Gruber
  • H Desal
  • I Wanke
  • D A Rüfenacht
چکیده

BACKGROUND AND PURPOSE FD technology enables reconstructive repair of otherwise difficult-to-treat intracranial aneurysms. These stentlike devices may induce progressive aneurysm thrombosis without additional implants and may initiate complete reverse vessel remodeling. The associated vascular biologic processes are as yet only partially understood. MATERIALS AND METHODS From 12 different centers, 13 cases of delayed postprocedural aneurysm rupture were recorded and analyzed. Symptom, aneurysm location and morphology, and the time elapsed from treatment until rupture were analyzed. RESULTS There were 10 internal carotid and 3 basilar artery aneurysms. Mean aneurysm diameter was 22 ± 6 mm. Eleven patients were symptomatic before treatment. A single FD was used for all saccular aneurysms, while fusiform lesions were treated by using multiple devices. A supplementary loose coiling of the aneurysm was performed in 1 patient only. Ten patients developed early aneurysm rupture after FD treatment (mean, 16 days; range, 2-48 days); in 3 patients, rupture occurred 3-5 months after treatment. In all cases, most of the aneurysm cavity was thrombosed before rupture. The biologic mechanisms predisposing to rupture under these conditions are reviewed and discussed CONCLUSIONS FDs alone may modify hemodynamics in ways that induce extensive aneurysm thrombosis. Under specific conditions, however, instead of reverse remodeling and cicatrization, aggressive thrombus-associated autolysis of the aneurysm wall may result in delayed rupture.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fatal Basilar Aneurysm Rupture 6 Months Following Pipeline Flow Diversion Treatment

The introduction of flow diverters represents a major paradigm shift in the endovascular treatment of intracranial aneurysms from deconstructive, endosaccular, aneurysm treatment to reconstructive, endoluminal, diseased parent vessel treatment. The theoretical concept of flow diversion (FD) technology relies on the ability offlowdiverters to induce a change in arterial and intra-aneurysmal hemo...

متن کامل

Delayed spontaneous rupture of a posterior inferior cerebellar artery aneurysm following treatment with flow diversion: a clinicopathologic study.

In this report, we present the fatal spontaneous delayed rupture of a previously unruptured large PICA aneurysm following treatment with the PED. Pathology at postmortem examination has supported the theory that intra-aneurysmal thrombus may acutely destabilize the aneurysm wall. Aneurysms with an anatomic arrangement that promote continued flow into the neck may not be optimal candidates for t...

متن کامل

Topical Review Flow Diversion for Intracranial Aneurysms A Review

The introduction of flow diverters for treatment of intracranial aneurysms represents a major paradigm shift in the treatment of these lesions. The theoretical hallmark of flow diverters is the treatment of the diseased segment harboring the aneurysm instead of treating the aneurysm itself. Flow diverters are designed to induce disruption of flow near the aneurysm neck while preserving flow int...

متن کامل

Flow diversion for intracranial aneurysms: a review.

The introduction of flow diverters for treatment of intracranial aneurysms represents a major paradigm shift in the treatment of these lesions. The theoretical hallmark of flow diverters is the treatment of the diseased segment harboring the aneurysm instead of treating the aneurysm itself. Flow diverters are designed to induce disruption of flow near the aneurysm neck while preserving flow int...

متن کامل

Aneurysm rupture following treatment with flow-diverting stents: computational hemodynamics analysis of treatment.

BACKGROUND AND PURPOSE Flow-diverting approaches to intracranial aneurysm treatment had many promising early results, but recent apparently successful treatments have been complicated by later aneurysm hemorrhage. We analyzed 7 cases of aneurysms treated with flow diversion to explore the possible rupture mechanisms. MATERIALS AND METHODS CFD analysis of pre- and posttreatment conditions was ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • AJNR. American journal of neuroradiology

دوره 32 1  شماره 

صفحات  -

تاریخ انتشار 2011