Diagnosing Crohn's disease: an economic analysis comparing wireless capsule endoscopy with traditional diagnostic procedures.
نویسندگان
چکیده
The purpose of this study was to review economic considerations related to establishing a diagnosis of Crohn's disease, and to compare the costs of a diagnostic algorithm incorporating wireless capsule endoscopy (WCE) with the current algorithm for diagnosing Crohn's disease suspected in the small bowel. Published literature, clinical trial data on WCE in comparison to other diagnostic tools, and input from clinical experts were used as data sources for (1) identifying contributors to the costs of diagnosing Crohn's disease; (2) exploring where WCE should be placed within the diagnostic algorithm for Crohn's; and (3) constructing decision tree models with sensitivity analyses to explore costs (from a payor perspective) of diagnosing Crohn's disease using WCE compared to other diagnostic methods. Literature review confirms that Crohn's disease is a significant and growing public health concern from clinical, humanistic and economic perspectives, and results in a long-term burden for patients, their families, providers, insurers, and employers. Common diagnostic procedures include radiologic studies such as small bowel follow through (SBFT), enteroclysis, CT scans, ultrasounds, and MRIs, as well as serologic testing, and various forms of endoscopy. Diagnostic costs for Crohn's disease can be considerable, especially given the cycle of repeat testing due to the low diagnostic yield of certain procedures and the inability of current diagnostic procedures to image the entire small bowel. WCE has a higher average diagnostic yield than comparative procedures due to imaging clarity and the ability to visualize the entire small bowel. Literature review found the average diagnostic yield of SBFT and colonoscopy for work-up of Crohn's disease to be 53.87%, whereas WCE had a diagnostic yield of 69.59%. A simple decision tree model comparing two arms--colonoscopy and SBFT, or WCE--estimates that WCE produces a cost savings of 291dollars for each case presenting for diagnostic work-up for Crohn's. Sensitivity analysis varying diagnostic yields of colonoscopy and SBFT vs. WCE demonstrates that WCE is still less costly than SBFT and colonoscopy even at their highest reported yields, as long as the diagnostic yield of WCE is 64.10% or better. Employing WCE as a first-line diagnostic procedure appears to be less costly, from a payor perspective, than current common procedures for diagnosing suspected Crohn's disease in the small bowel. Although not addressed in this model, earlier diagnosis with WCE (due to higher diagnostic yield) also could lead to earlier management, improved quality of life and workplace productivity for people with Crohn's disease.
منابع مشابه
Role of wireless capsule endoscopy in reclassifying inflammatory bowel disease in children.
OBJECTIVE To evaluate the role of wireless capsule endoscopy in identifying small bowel lesions in pediatric patients with newly diagnosed colonic inflammatory bowel disease (IBD) type unclassified (IBDU), and to assess whether capsule endoscopy findings result in altered patient management. METHODS Ten pediatric patients recently diagnosed with IBDU through standard investigations were recru...
متن کاملAcute small bowel perforation after wireless capsule endoscopy in a patient with Crohn’s disease: a case report
INTRODUCTION Wireless capsule endoscopy is an important tool for minimally invasive evaluation of the small bowel, allowing improved diagnostic yield with low complication rates relative to traditional modalities. Recently however, reports on small bowel perforation after wireless capsule endoscopy have surfaced. Here we present the first case of acute small bowel perforation in a middle-aged m...
متن کاملThe Study of Upper Gastrointestinal Endoscopy in Patients with Inflammatory Bowel Disease and Ulcerative Colitis
Background and aims: In diagnosing inflammatory bowel disease, one of diagnostic way is upper gastrointestinal endoscopy, which helps in differential diagnosis of unspecified colitis as well. The aim of this study was to investigate the necessity of upper gastrointestinal endoscopy in patients with inflammatory bowel disease. Materials and Methods: In this descriptive cross-sectional...
متن کاملWireless Capsule Endoscopy Detects Meckel's Diverticulum in a Child with Unexplained Intestinal Blood Loss
Meckel's diverticulum (MD) is the most common congenital anomaly of the gastrointestinal (GI) tract, affecting about 2% of the population. Most cases of Meckel's diverticula are asymptomatic. The diagnosis of symptomatic MD is often difficult to make. We report the case of an 8-year-old boy who presented with GI bleeding due to MD. The diagnostic difficulties after an initial negative endoscopi...
متن کاملDiagnosis of small bowel Crohn's disease: a prospective comparison of capsule endoscopy with magnetic resonance imaging and fluoroscopic enteroclysis.
BACKGROUND AND AIMS The diagnostic yield of capsule endoscopy (CE) compared with magnetic resonance imaging (MRI) in small bowel Crohn's disease is not well established. We prospectively investigated CE, MRI, and double contrast fluoroscopy in patients with suspected small bowel Crohn's disease. METHODS Fifty two consecutive patients (39 females, 13 males) were investigated by MRI, fluoroscop...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Disease management : DM
دوره 7 4 شماره
صفحات -
تاریخ انتشار 2004