Some sources of error in measuring regional blood flow with radioactive microspheres.
نویسندگان
چکیده
BUCKBERG, GERALD D., JOHN C. LUCK, D. BRUCE PAYNE, JULIEN I. E. HOFFMAN, JOSEPH P. ARCHIE, AND DAVID E. FIXLER. Some sources of error in measuring regional blood flow with radioactive microspheres. J. Appl. Physiol. 3 l(4) : 538-604. 197 1 .-Radioactive microspheres (8-50 p diameter) distribute in proportion to regional blood flow so that their concentrations in all arteries should be similar but for random variation. Varying numbers of microspheres were injected into the left atrium and ventricles of lambs, sheep, and dogs, and microsphere concentrations were measured in samples drawn simultaneously from two or more arteries (femoral, carotid, or aorta), in the free walls of the left and right ventricles and both kidneys. Coronary and renal blood flows were measured with microspheres (using peripheral reference samples) and by independent methods. Despite some nonrandomness (poor mixing) errors were usually under 20% for all injection and sampling sites in both species as long as each sample had over 400 microspheres; lesser numbers caused errors up to 1 13y0. Variability was less in dogs than sheep, less for left atria1 injections, but equivalent in all arteries. Coronary and renal flows by microspheres were usually within 20y0 and 6%, respectively, of measured flow. The greatest precision occurs on injection of the largest number of microspheres consistent with no physiological changes.
منابع مشابه
Measurement of pulpal blood flow in dogs with nonradioactive colored microspheres.
The viability of dental pulp depends largely on regional blood flow, as in other organs. Measurement of absolute pulpal blood flow (PBF) and comparisons with blood flow in other organs allow the prediction of microvascular regulation in dental pulp. In previous studies, PBF was measured in dogs mainly with radioactive microspheres. However, this established technique is inaccessible to many inv...
متن کاملStable labeled microspheres to measure perfusion: validation of a neutron activation assay technique.
Neutron activation is an accurate analytic method in which trace quantities of isotopes of interest in a sample are activated and the emitted radiation is measured with high-resolution detection equipment. This study demonstrates the application of neutron activation for the measurement of myocardial perfusion using stable isotopically labeled microspheres. Stable labeled and standard radiolabe...
متن کاملEvaluation of nonradioactive, colored microspheres for measurement of regional myocardial blood flow in dogs.
Measurement of regional myocardial blood flow (RMBF) is crucial in experimental studies of myocardial ischemia and reperfusion in dogs. The standard measurement technique uses radioactive microspheres; however, not all institutions are able to dispose of radioactive waste and therefore cannot make use of this method. We tested a new, nonradioactive microsphere, labeled with colors instead of nu...
متن کاملHigh spatial resolution measurements of organ blood flow in small laboratory animals.
With the use of a newly developed Imaging Cryomicrotome to determine the spatial location of fluorescent microspheres in organs, we validate and report our processing algorithms for measuring regional blood flow in small laboratory animals. Microspheres (15-microm diameter) of four different fluorescent colors and one radioactive label were simultaneously injected into the left ventricle of a p...
متن کاملComparison of regional blood flow values measured by radioactive and fluorescent microspheres.
Fluorescent microspheres (FM) have become an attractive alternative to radioactive microspheres (RM) for the measurement of regional blood flow (RBF). The aim of the present study was to investigate the comparability of both methods by measuring RBF with FM and RM. Eight anaesthetised pigs received simultaneous, left atrial injections of FM and RM with a diameter of 15 microm at six different t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of applied physiology
دوره 31 4 شماره
صفحات -
تاریخ انتشار 1971