Temporary percutaneous right ventricular support using a centrifugal pump in patients with postoperative acute refractory right ventricular failure after left ventricular assist device implantation.

نویسندگان

  • Assad Haneya
  • Alois Philipp
  • Thomas Puehler
  • Leopold Rupprecht
  • Reinhard Kobuch
  • Michael Hilker
  • Christof Schmid
  • Stephan W Hirt
چکیده

OBJECTIVE Acute right ventricular (RV) failure is a life-threatening condition with a poor prognosis, and sometimes the use of mechanical circulatory support is inevitable. In this article, we describe our experience using a centrifugal pump as a temporary percutaneous right ventricular assist device (RVAD) in patients with postoperative acute refractory RV failure after left ventricular assist device (LVAD) implantation. METHODS We retrospectively reviewed eight consecutive patients with acute RV failure who underwent temporary percutaneous RVAD implantation using a centrifugal pump after LVAD implantation between April 2008 and February 2011. A Dacron graft was attached to the main pulmonary artery and passed through a subxiphoid exit, where the outflow cannula was inserted. The inflow cannula was percutaneously cannulated using Seldinger's technique in the femoral vein. The chest was definitely closed. The technique allowed bedside removal, avoiding chest re-opening. RESULTS The median patient age was 52 years (range: 41-58). The median duration of support was 14 days (range: 12-14). RV systolic function improved; central venous pressure and mean pulmonary artery pressure decreased significantly after RVAD support. In three patients, an oxygenator was integrated into the RVAD due to impaired pulmonary function. Six patients were successfully weaned. Five patients survived to hospital discharge. Technical problems or serious complications concerning decannulation were not observed. CONCLUSION This report suggests that implantation of temporary percutaneous RVAD using a centrifugal pump is a safe alternative in the treatment of postoperative acute refractory RV failure. Ease of device implantation, weaning, explantation, and limited number of complications justify a liberal use.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Application of centrifugal pump in right ventricular failure due to pulmonary artery hypertension. (A case report)

Background: It has not been yet developed a ost suitable method to treat right ventricular failure due to pulmonar artery hypertention resulted from ventricular arrhythia. Though some case reports about patients ready to heart transplant using left assist device or biventral assist device as bridge have been published in Journals, but nocase concerning application of centrifugal pump for treatm...

متن کامل

Editorial comment: Adverse events in long-term ventricular assist device therapy.

the higher risk of developing a thrombosis anyway. In conclusion, compared with the other study results, our data suggest that a notably mild anticoagulation protocol does not increase the risk of severe thrombo-embolic events in the early and late postoperative period after the implantation of the HM II CW LVAD. Furthermore, this mild regime is helpful in reducing the still unacceptably high i...

متن کامل

Mechanical circulatory support for right ventricular failure.

OBJECTIVES The aim of this study was to explore the clinical utility of a commercially available centrifugal flow pump as a centrifugal flow-right ventricular support device (CF-RVSD) in patients with right ventricular failure (RVF). BACKGROUND RVF is associated with high in-hospital mortality. Limited data regarding efficacy of the CF-RVSD for RVF exist. METHODS We retrospectively reviewed...

متن کامل

Design an Equivalent Left Ventricular Assist Device for Medical Equipment Labs

LVAD is a mechanical pump supporting a weak heart function and blood flow. Sometimes, the heart may not recover fast enough to take over the pumping action immediately after surgery, in such patients a temporary support device has been employed to maintain the pumping action until the patient’s own heart recovers. This device can be considered as a temporary alternative before the process of ar...

متن کامل

Concurrent Left Ventricular Assist Device (LVAD) Implantation and Percutaneous Temporary RVAD Support via CardiacAssist Protek-Duo TandemHeart to Preempt Right Heart Failure

Right ventricular failure (RVF) is an unfortunate complication that continues to limit outcomes following durable left ventricular assist device (LVAD) implantation. Despite several 'RVF risk scores' having been proposed, preoperative prediction of post-LVAD RVF remains a guesstimate at best. Current strategies for institution of temporary RVAD support are invasive, necessitate additional re-th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery

دوره 41 1  شماره 

صفحات  -

تاریخ انتشار 2012