Magnification error of digital x rays on the computer screen.

نویسندگان

  • S Ranjitkar
  • D Prakash
  • R Prakash
چکیده

Templating x-rays of total hip and knee replacements pre-operatively are important to plan surgery. This is usually done using acetate templates of the prosthesis on hard copies of the x-ray. With the change in practice, to use digital x-rays on computer screens instead of hard copies, it is important to assess if acetate templates can be used for digital x-rays on the computer screen. This is a retrospective x-ray study of 19 hip replacements and 30 knee replacements to assess their magnification using the Patient Archiving Computerised System (PACS) software. This study was done to assess the accuracy of magnification, using acetate templates over a computer screen. In total hip replacement, the outer cup diameter was also measured using the digital measurement scale. The mean magnification was 0.59 for the acetabular cup and the femoral stem in total hip replacement and 0.48 for the femoral and tibial implant in total knee replacement. The mean difference in cup diameter comparing to the real size was an excess of 10.21 mm. The study showed over-magnified hip and knee x-rays thus suggesting that acetate templates and measurement scales on PACS was not reliable.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

کاربرد فناوری‌های کمکی رایانه‌ای برای دانش‌آموزان کم‌بینا در فرایند یاددهی - یادگیری

The communication and information technology is creating a variation of change and transform in the entire education system. One of the powerful manifestations of this communication and information technology is the use of computer in training. Computer has much potential in education of exceptional students, especially, for students with visual impairment. By applying the computer and suppleme...

متن کامل

Image quality enhancement in digital panoramic radiograph

One of the most common positioning errors in panoramic radiography is palatoglossal air space above the apices of the root of maxillary teeth. It causes a radiolucency obscuring the apices of maxillary teeth. In the case of this positioning error, the imaging should be repeated. This causes the patient be exposed to radiation again. To avoid the repetition of exposing harmful X-rays to the pati...

متن کامل

Qualitative Evaluation of Digital Hand X-rays is Not a Reliable Method to Assess Bone Mineral Density

Object: The gold standard for evaluating bone mineral density is dual energy x-ray absorptiometry (DEXA).  Prior studies have shown poor reliability using analog wrist X-rays in diagnosing osteoporosis. Our goal was to investigate if there was improved diagnostic value to visual assessment of digital hand X-rays in osteoporosis screening. We hypothesized that similar to analog counterparts, dig...

متن کامل

A simple and convenient method guide to determine the magnification of digital X-rays for preoperative planning in total hip arthroplasty

Scaling of anteroposterior digital pelvic X-rays with variable magnification is the premise for accurate preoperative planning of total hip replacement with digital templating. Conn's method of placing a marker of known diameter beside the thigh at the level of the femur has been reproduced in many studies and confirmed as one of the most accurate methods. But in our experience, it is inconveni...

متن کامل

Quadrature Amplitude Modulated Digital Radio Transmission Modeling and Simulation

Computer aided design and computer aided modeling tools are becoming increasingly important in the design and performance evaluation of communication systems. In this work, we report on the computer simulation modeling study of terrestrial digital microwave radio transmission, using Block Oriented System Simulator package (BOSS). The work concentrates on semi-analytical error rate evaluation in...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Nepal Medical College journal : NMCJ

دوره 16 2-4  شماره 

صفحات  -

تاریخ انتشار 2014