Lung deposition of nebulised pentamidine in children.
نویسندگان
چکیده
BACKGROUND Nebulised pentamidine is effective for preventing Pneumocystis carinii pneumonia in adults with acquired immunodeficiency syndrome. The nebuliser dose required to produce equivalent lung concentrations of pentamidine in children is unknown. This study was performed to measure pulmonary pentamidine deposition in children and to relate this to age, ventilation pattern, and body size. METHODS Nebulised pentamidine (50 mg in 6 ml saline) was administered to 12 children (including one with lymphocytic interstitial pneumonitis) and to six adults with human immunodeficiency virus infection using a Respirgard II nebuliser. Technetium-99m labeled colloidal human serum albumin was used as an indirect marker for pentamidine and deposition in the lungs was detected by a gamma camera. RESULTS Absolute deposition of pentamidine was not related to age, height, weight, spirometry, or ventilation characteristics. Deposition, as a mean (SD) percentage of nebuliser output, was similar in children aged 8-11 years (5.5(2.4)%), teenagers aged 12-15 years (7.2(2.2)%) and adults (7.1(2.6)%). Aerosol concentration within the lungs (% nebuliser output deposited/predicted total lung capacity) was therefore higher in children (1.9(1.5)%/1) and teenagers (1.9(0.7)%/1) than in adults (1.0(0.7%)/1), and was negatively correlated with height (r = -0.69) and weight (r = -0.50). Deposition of aerosol in the region of the large central airways was particularly marked in children. Small reductions in forced expiratory volume in one second and forced vital capacity after treatment did not differ significantly between adults and children and visual analogue scores of subjective adverse effects did not vary with age. CONCLUSIONS These results suggest that children probably require lower nebuliser pentamidine doses to produce lung pentamidine concentrations equivalent to those found to be effective for preventing P carinii pneumonia in adults using the Respirgard II nebuliser.
منابع مشابه
Pulmonary deposition of nebulised pentamidine isethionate: effect of nebuliser type, dose, and volume of fill.
An estimate of the absolute pulmonary deposition of nebulised pentamidine isethionate was obtained in nine patients with AIDS. Two nebuliser systems were compared, System 22 Mizer (Medic-Aid) and Respirgard II (Marquest), with 50 and 150 mg doses of pentamidine in a 3 ml solution driven by an air flow of 6 l/min with the patient in the sitting position. The 50 mg pentamidine dose was repeated w...
متن کاملWhich apparatus for inhaled pentamidine? A comparison of pulmonary deposition via eight nebulisers.
Aerosolised pentamidine 300 mg in 5 or 6 ml solution was administered via 8 different nebuliser systems to 12 patients with acquired immunodeficiency syndrome. Using 99mTc human serum albumin as an indirect marker for pentamidine, pulmonary, extrapulmonary (gastric and oropharyngeal) and alveolar deposition of pentamidine were measured using a gamma camera. Side effects (visual analogue scales)...
متن کاملEffect of terbutaline on bronchoconstriction induced by nebulised pentamidine.
The severity, duration, and reversibility of pentamidine induced bronchial narrowing was studied with and without pretreatment with nebulised terbutaline 10 mg in an open study of 40 patients seropositive for the human immunodeficiency virus (HIV). All subjects received pentamidine 300 mg in 5 ml water via an Acorn System 22 jet nebuliser. The forced expiratory volume in one second (FEV1) fell ...
متن کاملNebuliser therapy in childhood.
Jet and ultrasonic nebulisers continue to be of medications and this may reduce the deposition of the drug in the periphery of the lungs. The value in childhood. Nebulised therapy provides a portal of entry for systemic drug treatment effect of crying on aerosol deposition is not known. as well as for the direct treatment of respiratory diseases. Work by Collis has focused attention on the tota...
متن کاملNebulised pentamidine as treatment for Pneumocystis carinii pneumonia in the acquired immunodeficiency syndrome.
Nebulised pentamidine was used to treat 30 patients with Pneumocystis carinii pneumonia. Fourteen patients (group 1) received pentamidine isethionate 4 mg/kg (six patients) or 8 mg/kg (eight patients) via a standard jet nebuliser (Acorn, system 22) with a flow rate of 8 l/min. The aerosol droplets had a mass median aerodynamic diameter of 2.6 microns (geometric standard deviation (GSD) 2.9) and...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Thorax
دوره 48 3 شماره
صفحات -