State of the market. A review of ambulatory blood pressure monitoring devices.
نویسندگان
چکیده
The introduction of 24-hour ambulatory blood pressure measurement into clinical practice created a large market for ambulatory blood pressure measurement devices. Forty-three such devices from 31 manufacturers or suppliers are now available to satisfy a market demand that is likely to increase. The aim of this article is to identify the devices available and then to examine critically any validation studies assessing accuracy and performance. Of the 43 devices available 18 have been validated according to the protocols of the Association for the Advancement of Medical Instrumentation (AAMI) or the British Hypertension Society (BHS) in 25 reported studies. In 9 of these studies the protocol was not adhered to, and the results, which are therefore questionable, are noted but not considered further. Fourteen devices were evaluated according to the accuracy criteria of both protocols, and of these 9 fulfilled the requirements. From this review of 43 devices on the market it may be concluded that, at the time of writing, there is published evidence for only 9 devices meeting the generally accepted AAMI and BHS criteria for accuracy and performance; these are the A&D TM-2420 models 6 and 7 and TM-2421, CH-Druck, Nissei ABPM DS-240, Profilomat, QuietTrak, and SpaceLabs SL-90202 and SL-90207.
منابع مشابه
Automated blood pressure measurement: state of the market in 1998 and the need for an international validation protocol for blood pressure measuring devices.
The market for blood pressure measuring devices is increasing rapidly. A vast market for self-measuring devices has existed for many years and this continues to grow. There is also a large market for autoated devices in specialized hospital areas, such as operating theatres and intensive care units. Since the introduction of ambulatory blood pressure monitoring into clinical practice, a growing...
متن کاملEffects of Ramadan fasting on ambulatory blood pressure in hypertensive patients
Background: Previous studies have indicated that Ramadan fasting has beneficial effects on cardiovascular risk factors, specially blood pressure and heart rate. In the present study, the effect of Ramadan fasting on 24-hour ambulatory blood pressure and heart rate has been investigated. Materials and Methods: This prospective observational study was conducted on two groups of individuals. Six p...
متن کاملContinuous and Cuffless Blood Pressure Monitoring Based on ECG and SpO2 Signals By Using Microsoft Visual C Sharp
Background: One of the main problems especially in operating room and monitoring devices is measurement of Blood Pressure (BP) by sphygmomanometer cuff.Objective: In this study we designed a new method to measure BP changes continuously for detecting information between cuff inflation times by using vital signals in monitoring devices. This will be achieved by extraction of the time difference ...
متن کاملNon-invasive Optical Techniques for determination of blood Glucose levels: A Review Article
This article reviews the development of non-invasive optical techniques for determination of blood glucose concentrations in diabetic patients. Early diagnosis and daily management are essential for ensuring the healthy life of diabetic patients. The determination of blood glucose concentration with common devices involves the chemical analysis of blood samples, which are obtained by pricking t...
متن کاملAmbulatory blood pressure measurement is indispensable to good clinical practice.
The traditional technique of blood pressure measurement is being phased out in most countries and is being replaced by automated measurement. The era of automated blood pressure measurement brings its own problems, not least being the need to evaluate blood pressure measuring devices independently for accuracy. Towards this end, the Working Group on Blood Pressure Monitoring of the European Soc...