Evaluation of Biofuel Cells with Hemoglobin as Cathodic Electrocatalysts for Hydrogen Peroxide Reduction on Bare Indium-Tin-Oxide Electrodes

نویسندگان

  • Yusuke Ayato
  • Naoki Matsuda
چکیده

A biofuel cell (BFC) cathode has been developed based on direct electron transfer (DET) of hemoglobin (Hb) molecules with an indium-tin-oxide (ITO) electrode and their electrocatalysis for reduction of hydrogen peroxide (H2O2). In this study, the ITO-coated glass plates or porous glasses were prepared by using a chemical vapor deposition (CVD) method and examined the electrochemical characteristics of the formed ITO in pH 7.4 of phosphate buffered saline (PBS) solutions containing and not containing Hb. In half-cell measurements, the reduction current of H2O2 due to the electrocatalytic activity of Hb increased with decreasing electrode potential from around 0.1 V versus Ag|AgCl|KCl(satd.) in the PBS solution. The practical open-circuit voltage (OCV) on BFCs utilizing H2O2 reduction at the Hb-ITO cathode with a hydrogen (H2) oxidation anode at a platinum (Pt) electrode was expected to be at least 0.74 V from the theoretical H2 oxidation potential of −0.64 V versus Ag|AgCl|KCl(satd.) in pH 7.4. The assembled single cell using the ITO-coated glass plate showed the OCV of 0.72 V and the maximum power density of 3.1 μW cm. The maximum power per single cell was recorded at 21.5 μW by using the ITO-coated porous glass.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A simple biofuel cell cathode with human red blood cells as electrocatalysts for oxygen reduction reaction.

A red blood cell (RBC) from human exhibited direct electron transfer (DET) activity on a bare indium tin oxide (ITO) electrode. A formal potential of -0.152 V vs. a silver-silver chloride saturated potassium chloride (Ag|AgCl|KCl(satd.)) was estimated for the human RBC (type AB) from a pair of redox peaks at around 0.089 and -0.215 V (vs. Ag|AgCl|KCl(satd.)) on cyclic voltammetric (CV) measurem...

متن کامل

Platinum Nanoparticles (PtNPs) - Laccase Assisted Biocathode Reduction of Oxygen for Biofuel Cells

Reduction of dioxygen catalyzed by laccase was studied at platinum nanoparticles (PtNPs) modified electrodes. PtNPs with laccase are directly fabricated on glassy carbon electrode (GCE) and indium tin oxide electrode (ITO) by simple process. The PtNPs/laccase modified ITO electrode surface has been studied in detail using atomic force microscopy (AFM). This PtNPs/laccase modified GCE effectivel...

متن کامل

Spontaneous Deposition of Prussian Blue on Multi-Walled Carbon Nanotubes and the Application in an Amperometric Biosensor

A simple method has been developed for the spontaneous deposition of Prussian blue (PB) particles from a solution containing only ferricyanide ions onto conducting substrates such as indium tin oxide glass, glassy carbon disk and carbon nanotube (CNT) materials. Formation of PB deposits was confirmed by ultraviolet-visible absorption spectrometry and electrochemical techniques. The surface morp...

متن کامل

A Biosensor for Hydrogen Peroxide Based on Single Walled Carbon Nanotube and Metal Oxide Modified ITO Electrode

A novel approach has been developed for a highly sensitive, fast responding and stable monoenzymatic amperometric biosensor for the detection of hydrogen peroxide using coimmobilized the SWNT and methylene blue (MB) into the metal oxide (SnO2) derived organically modified sol-gel glasses (ormosil). Nafion (NAF) was dispersed within the ormosil matrix to enhance the electron transportation in th...

متن کامل

Fabrication of a hydrogen peroxide biosensor based on a self-assemble composite oxide film.

A titania film with horseradish peroxidase (HRP) was immobilized on indium tin oxide (ITO) electrodes to act as a biosensor of hydrogen peroxide via the self-assembling and sol-gel route. The film was characterized by the atomic functional microscopy, electrochemical and UV-vis spectroscopy methods. The resulting biosensor exhibited fast amperometric response and good stability to hydrogen pero...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013