Dynamic analysis of chemical eye burns using high-resolution optical coherence tomography.
نویسندگان
چکیده
The use of high-resolution optical coherence tomography (OCT) to visualize penetration kinetics during the initial phase of chemical eye burns is evaluated. The changes in scattering properties and thickness of rabbit cornea ex vivo were monitored after topical application of different corrosives by time-resolved OCT imaging. Eye burn causes changes in the corneal microstructure due to chemical interaction or change in the hydration state as a result of osmotic imbalance. These changes compromise the corneal transparency. The associated increase in light scattering within the cornea is observed with high spatial and temporal resolution. Parameters affecting the severity of pathophysiological damage associated with chemical eye burns like diffusion velocity and depth of penetration are obtained. We demonstrate the potential of high-resolution OCT for the visualization and direct noninvasive measurement of specific interaction of chemicals with the eye. This work opens new horizons in clinical evaluation of chemical eye burns, eye irritation testing, and product testing for chemical and pharmacological products.
منابع مشابه
Analysis of hydrofluoric acid penetration and decontamination of the eye by means of time-resolved optical coherence tomography.
So far the study of chemical burns has lacked techniques to define penetration kinetics and the effects of decontamination within biological structures. In this study, we aim to demonstrate that high-resolution optical coherence tomography (HR-OCT) can close this gap. Rabbit corneas were exposed ex vivo to 2.5% hydrofluoric acid (HF) solution, and microstructural changes were monitored in the t...
متن کاملDevelopment of an Advanced Optical Coherence Tomography System for Radiation Dosimetry
Introduction: According to the literature, optical coherence tomography (OCT) can be used measure radiation absorbed dose. This study was carried out to design a computed tomography system for the calculation of absorbed dose and optimization of dose delivery in radiotherapy using gel dosimeters. Material and Methods: An advanced charge-coupled device based OCT system was developed in laborator...
متن کاملبررسی پایایی و تکرار پذیری دستگاه Spectral domain optical coherence tomography در اندازه گیری ضخامت ماکولا در چشمهای طبیعی قبل و بعد از گشاد کردن مردمک
Background: optical coherence tomography is one of the most valuable imaging techniques in the evaluation of macula. Objective: to investigate the repeatability and reproducibility of OCT in measuring the macular thickness in normal eyes before and after pupil dilation. Methods: A total of 44 eyes were enrolled. All subjects underwent macular thickness measurement using the Cirrus SD-OCT ma...
متن کاملExperimental Visualization of Labyrinthine Structure with Optical Coherence Tomography
Introduction:Visualization of inner ear structures is a valuable strategy for researchers and clinicians working on hearing pathologies. Optical coherence tomography (OCT) is a high-resolution imaging technology which may be used for the visualization of tissues. In this experimental study we aimed to evaluate inner ear anatomy in well-prepared human labyrinthine bones.Materials and Methods:Thr...
متن کاملComparison of Choroidal Thickness in Psoriasis and Control Groups Using Optical Coherence Tomography
Background and Objective: One of the most common extracutaneous complications in psoriasis patients is ocular complications, which is controversial concerning its effect on choroidal thickness. This study aimed to compare the psoriasis patients with healthy individuals in terms of the thickness of the choroidal layer using the optical coherence tomography technique. Materials and Methods: In t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of biomedical optics
دوره 12 4 شماره
صفحات -
تاریخ انتشار 2007