RE: Dipstick Spot urine pH does not accurately represent 24 hour urine PH measured by an electrode

نویسنده

  • Viroj Wiwanitkit
چکیده

OBJECTIVES To determine whether spot urine pH measured by dipstick is an accurate representation of 24 hours urine pH measured by an electrode. MATERIALS AND METHODS We retrospectively reviewed urine pH results of patients who presented to the urology stone clinic. For each patient we recorded the most recente pH result measured by dipstick from a spot urine sample that preceded the result of a 24-hour urine pH measured by the use of a pH electrode. Patients were excluded if there was a change in medications or dietary recommendations or if the two samples were more than 4 months apart. A difference of more than 0.5 pH was considered na inaccurate result. RESULTS A total 600 patients were retrospectively reviewed for the pH results. The mean difference in pH between spot urine value and the 24 hours collection values was 0.52±0.45 pH. Higher pH was associated with lower accuracy (p<0.001). The accuracy of spot urine samples to predict 24-hour pH values of <5.5 was 68.9%, 68.2% for 5.5 to 6.5 and 35% for >6.5. Samples taken more than 75 days apart had only 49% the accuracy of more recent samples (p<0.002). The overall accuracy is lower than 80% (p<0.001). Influence of diurnal variation was not significant (p=0.588). CONCLUSIONS Spot urine pH by dipstick is not an accurate method for evaluation of the patients with urolithiasis. Patients with alkaline urine are more prone to error with reliance on spot urine pH.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optimization of urinary dipstick pH: Are multiple dipstick pH readings reliably comparable to commercial 24-hour urinary pH?

PURPOSE Accurate measurement of pH is necessary to guide medical management of nephrolithiasis. Urinary dipsticks offer a convenient method to measure pH, but prior studies have only assessed the accuracy of a single, spot dipstick. Given the known diurnal variation in pH, a single dipstick pH is unlikely to reflect the average daily urinary pH. Our goal was to determine whether multiple dipsti...

متن کامل

A Comparison of 4- and 24-Hour Urine Samples for the Diagnosis of Proteinuria in Pregnancy

Background: Preeclampsia is a serious complication of pregnancy, and it is vital to diagnosis the condition as early as possible. Proteinuria is an important symptom of preeclampsia, and repeated urine analysis to screen for the condition is part of the standard antenatal care. The purpose of this study was to determine the correlation between 4- and 24-hour urine total protein values to examin...

متن کامل

Evaluation of rapid diagnostic methods of urinary protein estimation in patients of preeclampsia of advanced gestational age.

BACKGROUND 24-h urine protein is traditionally used as a gold standard method for protein estimation. Because of the operational difficulty, there is the necessity to use rapid, convenient, and reliable method of proteinuria estimation. AIM We carried out this study to compare the two rapid methods of protein estimation: dipstick method and spot urine protein creatinine ratio (UPCR) with that...

متن کامل

Low urine pH: a novel feature of the metabolic syndrome.

BACKGROUND AND OBJECTIVES The metabolic syndrome is associated with alterations in renal function. An overly acidic urine has been described as a renal manifestation of the metabolic syndrome in patients with kidney stone disease. This study examined the association between the metabolic syndrome and urine pH in individuals without a history of nephrolithiasis. DESIGN, SETTING, PARTICIPANTS, ...

متن کامل

Dipstick measurements of urine specific gravity

Aim—To evaluate the reliability of dipstick measurements of urine specific gravity (U-SG). Methods—Fresh urine specimens were tested for urine pH and osmolality (U-pH, U-Osm) by a pH meter and an osmometer, and for U-SG by three diVerent methods (refractometry, automatic readout of a dipstick (Clinitek-50), and (visual) change of colour of the dipstick). Results—The correlations between the vis...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 42  شماره 

صفحات  -

تاریخ انتشار 2016